科研成果详情

题名Biocompatible Graphene Oxide-Based Glucose Biosensors
作者
发表日期2010-05-04
发表期刊LANGMUIR   影响因子和分区
语种英语
原始文献类型Article
关键词Aldehydes Amines Biocompatibility Diagnosis Electrodes Enzyme electrodes Glucose Glucose oxidase Glucose sensors Cell attachments Clinical diagnosis Covalent attachment Glucose biosensor Graphene oxide nanosheets Reproducibilities Retinal pigment epithelium Storage stability
其他关键词LARGE-AREA ; ELECTRODE ; IMMOBILIZATION ; DIAMOND ; FILMS
摘要This letter demonstrates that a novel, highly efficient enzyme electrode can be directly obtained using covalent attachment between carboxyl acid groups of graphene oxide sheets and amines of glucose oxidase. The resulting biosensor exhibits a broad linear range up to 28 mM.mm(-2) glucose with a sensitivity of 8.045 mA.cm(-2), M-1. The glucose oxidase-immobilized graphene oxide electrode also shows a reproducibility and a good storage stability, suggesting potentials for a wide range of practical applications. The biocompatibility of as-synthesized graphene oxide nanosheets with human cells, especially retinal pigment epithelium (RPE) cells, was in for the first time in the present work. Microporous graphene oxide exhibits good biocompatibility and has potential advantages with respect to cell attachment and proliferation, leading to opportunities for using graphene-based biosensors for the clinical diagnosis.
资助项目Zhejiang Department of Education [Y200906587]; Ministry of Science and Technology of ChinaMinistry of Science and Technology, China [2009DFB30380]; Zhejiang Department of Science and Technology [2009C13019]
出版者AMER CHEMICAL SOC
出版地WASHINGTON
ISSN0743-7463
EISSN1520-5827
卷号26期号:9页码:6158-6160
DOI10.1021/la100886x
页数24
WOS类目Chemistry, Multidisciplinary ; Chemistry, Physical ; Materials Science, Multidisciplinary
WOS研究方向Chemistry ; Materials Science
WOS记录号WOS:000276969700018
收录类别SCIE ; EI ; PUBMED ; SCOPUS
EI入藏号20101812910724
EI主题词Graphene
URL查看原文
PubMed ID20349968
SCOPUSEID2-s2.0-77951686517
ESI高被引论文2020-01 ; 2020-03 ; 2020-05 ; 2020-09 ; 2020-11 ; 2021-01 ; 2021-03
通讯作者地址[Liu, Yong]Biomedical Engineering Academy,School of Ophthalmology and Optometry,Wenzhou Medical College,270 Xueyuan Road,China
Scopus学科分类Materials Science (all);Condensed Matter Physics;Surfaces and Interfaces;Spectroscopy;Electrochemistry
引用统计
被引频次:569[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符https://kms.wmu.edu.cn/handle/3ETUA0LF/6899
专题眼视光学院(生物医学工程学院)、附属眼视光医院
通讯作者Liu, Yong
作者单位
1.Biomedical Engineering Academy,School of Ophthalmology and Optometry,Wenzhou Medical College,270 Xueyuan Road,China;
2.Department of Chemical Engineering,Case Western Reserve University,10900 Euclid Avenue,United States;
3.College of Chemistry and Chemical Engineering,Shaan-xi University of Science and Technology,China
第一作者单位眼视光学院(生物医学工程学院)、附属眼视光医院
通讯作者单位眼视光学院(生物医学工程学院)、附属眼视光医院
第一作者的第一单位眼视光学院(生物医学工程学院)、附属眼视光医院
推荐引用方式
GB/T 7714
Liu, Yong,Yu, Dingshan,Zeng, Chao,et al. Biocompatible Graphene Oxide-Based Glucose Biosensors[J]. LANGMUIR,2010,26(9):6158-6160.
APA Liu, Yong, Yu, Dingshan, Zeng, Chao, Miao, Zongcheng, & Dai, Liming. (2010). Biocompatible Graphene Oxide-Based Glucose Biosensors. LANGMUIR, 26(9), 6158-6160.
MLA Liu, Yong,et al."Biocompatible Graphene Oxide-Based Glucose Biosensors".LANGMUIR 26.9(2010):6158-6160.

条目包含的文件

条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Liu, Yong]的文章
[Yu, Dingshan]的文章
[Zeng, Chao]的文章
百度学术
百度学术中相似的文章
[Liu, Yong]的文章
[Yu, Dingshan]的文章
[Zeng, Chao]的文章
必应学术
必应学术中相似的文章
[Liu, Yong]的文章
[Yu, Dingshan]的文章
[Zeng, Chao]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。