摘要Objective To determine the stability of fracture thoracic-lumber spine (T11~L3) fixed with crossbar-equipped pedicle screws. Method The thoracic-lumber spine segments (T11~L3) were obtained from calves. A wedge cut was performed on L1 vertebral body to produce a model resembling severe vertebral compressive fracture. Some of the fracture spine segments were fixed with pedicle screws with and without crossbar. Thus, 4 types of spine segments were available: (1) normal segments; (2) unfixed fracture; (3) fracture fixed with crossbar-equipped pedicle screws and (4) fracture fixed with pedicle screws without crossbar. The segmental stability was determined by measuring the range of motion (ROM) at directions of flexion/extension, left/right axial rotation and left/right lateral bending using a three-dimensional laser scanner. Each ROM was standardized into a stability potential index (SPI) for the comparison among 4 groups. Results Compared to unfixed fracture, both fixations significantly increase stability of injuried specimens at each motion direction. The stability of injured segment fix with crossbar-equipped pedicle screws is higher than that fixed without crossbar, but the difference does not reach statistically significant. Conclusions Pedicle screw fixation can significantly increase the stability of fracture spine. However, crossbar may not play a further role in raising fixative stability.
出版者Shanghai Jiaotong University School of Medicine
ISSN1004-7220
卷号25期号:2页码:100-104
页数11
收录类别EI ; SCOPUS
EI入藏号20102613045789
EI主题词Fracture
URL查看原文
SCOPUSEID2-s2.0-78651530896
文献类型期刊论文
条目标识符https://kms.wmu.edu.cn/handle/3ETUA0LF/34929
专题第一临床医学院(信息与工程学院)、附属第一医院_外科学_骨科
数字化医学与智能技术研究院
第二临床医学院,附属第二医院、育英儿童医院_外科学_骨科
作者单位
1.Department of Orthopedics, The First Affiliated Hospital of Wenzhou Medical College, Wenzhou 325000, China;
2.Department of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical College, Wenzhou 325027, China;
3.Institute of Digitized Medicine, Wenzhou Medical College, Wenzhou 325035, China
第一作者单位第一临床医学院(信息与工程学院)、附属第一医院_外科学_骨科
第一作者的第一单位第一临床医学院(信息与工程学院)、附属第一医院_外科学_骨科
推荐引用方式
GB/T 7714
Zhu, Min-Yu,Huang, Qi-Shan,Chi, Yong-Long,et al. Assessment for the stability of fracture thoracic-lumber spine(T11~L3) fixed with crossbar-equipped pedicle screws[J]. Yiyong Shengwu Lixue/Journal of Medical Biomechanics,2010,25(2):100-104.
APA Zhu, Min-Yu, Huang, Qi-Shan, Chi, Yong-Long, Wu, Li-Jun, Teng, Hong-Lin, & Wang, Jing. (2010). Assessment for the stability of fracture thoracic-lumber spine(T11~L3) fixed with crossbar-equipped pedicle screws. Yiyong Shengwu Lixue/Journal of Medical Biomechanics, 25(2), 100-104.
MLA Zhu, Min-Yu,et al."Assessment for the stability of fracture thoracic-lumber spine(T11~L3) fixed with crossbar-equipped pedicle screws".Yiyong Shengwu Lixue/Journal of Medical Biomechanics 25.2(2010):100-104.

条目包含的文件

条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Zhu, Min-Yu]的文章
[Huang, Qi-Shan]的文章
[Chi, Yong-Long]的文章
百度学术
百度学术中相似的文章
[Zhu, Min-Yu]的文章
[Huang, Qi-Shan]的文章
[Chi, Yong-Long]的文章
必应学术
必应学术中相似的文章
[Zhu, Min-Yu]的文章
[Huang, Qi-Shan]的文章
[Chi, Yong-Long]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。