题名 | Assessment for the stability of fracture thoracic-lumber spine(T11~L3) fixed with crossbar-equipped pedicle screws |
作者 | |
发表日期 | 2010-04-01 |
发表期刊 | Yiyong Shengwu Lixue/Journal of Medical Biomechanics 影响因子和分区 |
语种 | 中文 |
原始文献类型 | Journal article (JA) |
关键词 | Lumber Screws Stability Biomechanical Compressive fracture Internal fixation Monosegmental Motion direction Pedicle Range of motions Three-dimensional laser scanners |
摘要 | Objective To determine the stability of fracture thoracic-lumber spine (T11~L3) fixed with crossbar-equipped pedicle screws. Method The thoracic-lumber spine segments (T11~L3) were obtained from calves. A wedge cut was performed on L1 vertebral body to produce a model resembling severe vertebral compressive fracture. Some of the fracture spine segments were fixed with pedicle screws with and without crossbar. Thus, 4 types of spine segments were available: (1) normal segments; (2) unfixed fracture; (3) fracture fixed with crossbar-equipped pedicle screws and (4) fracture fixed with pedicle screws without crossbar. The segmental stability was determined by measuring the range of motion (ROM) at directions of flexion/extension, left/right axial rotation and left/right lateral bending using a three-dimensional laser scanner. Each ROM was standardized into a stability potential index (SPI) for the comparison among 4 groups. Results Compared to unfixed fracture, both fixations significantly increase stability of injuried specimens at each motion direction. The stability of injured segment fix with crossbar-equipped pedicle screws is higher than that fixed without crossbar, but the difference does not reach statistically significant. Conclusions Pedicle screw fixation can significantly increase the stability of fracture spine. However, crossbar may not play a further role in raising fixative stability. |
出版者 | Shanghai Jiaotong University School of Medicine |
ISSN | 1004-7220 |
卷号 | 25期号:2页码:100-104 |
页数 | 11 |
收录类别 | EI ; SCOPUS |
EI入藏号 | 20102613045789 |
EI主题词 | Fracture |
URL | 查看原文 |
SCOPUSEID | 2-s2.0-78651530896 |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/34929 |
专题 | 第一临床医学院(信息与工程学院)、附属第一医院_外科学_骨科 数字化医学与智能技术研究院 第二临床医学院,附属第二医院、育英儿童医院_外科学_骨科 |
作者单位 | 1.Department of Orthopedics, The First Affiliated Hospital of Wenzhou Medical College, Wenzhou 325000, China; 2.Department of Orthopedics, The Second Affiliated Hospital of Wenzhou Medical College, Wenzhou 325027, China; 3.Institute of Digitized Medicine, Wenzhou Medical College, Wenzhou 325035, China |
第一作者单位 | 第一临床医学院(信息与工程学院)、附属第一医院_外科学_骨科 |
第一作者的第一单位 | 第一临床医学院(信息与工程学院)、附属第一医院_外科学_骨科 |
推荐引用方式 GB/T 7714 | Zhu, Min-Yu,Huang, Qi-Shan,Chi, Yong-Long,et al. Assessment for the stability of fracture thoracic-lumber spine(T11~L3) fixed with crossbar-equipped pedicle screws[J]. Yiyong Shengwu Lixue/Journal of Medical Biomechanics,2010,25(2):100-104. |
APA | Zhu, Min-Yu, Huang, Qi-Shan, Chi, Yong-Long, Wu, Li-Jun, Teng, Hong-Lin, & Wang, Jing. (2010). Assessment for the stability of fracture thoracic-lumber spine(T11~L3) fixed with crossbar-equipped pedicle screws. Yiyong Shengwu Lixue/Journal of Medical Biomechanics, 25(2), 100-104. |
MLA | Zhu, Min-Yu,et al."Assessment for the stability of fracture thoracic-lumber spine(T11~L3) fixed with crossbar-equipped pedicle screws".Yiyong Shengwu Lixue/Journal of Medical Biomechanics 25.2(2010):100-104. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论