题名 | Use of the Anterior Chamber Maintainer in Trabeculectomy Following Vitrectomy |
作者 | |
发表日期 | 2011-03 |
发表期刊 | CURRENT EYE RESEARCH 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Article |
关键词 | Anterior chamber maintainer Complications Intraocular pressure Trabeculectomy Vitrectomy |
其他关键词 | AUTOMATED ENDOTHELIAL KERATOPLASTY ; INTRAOCULAR-LENS IMPLANTATION ; INCISION CATARACT-SURGERY ; VISCOELASTIC MATERIAL ; NUCLEUS MANAGEMENT ; PHACOEMULSIFICATION ; PRESSURE ; CAPSULE ; EYES |
摘要 | Methods: Trabeculectomy was performed on 51 secondary glaucoma patients (51 eyes), all of whom had undergone vitrectomy. During trabeculectomy, an ACM was placed in 27 eyes (group A), but not in the remaining 24 (group B). Intra- and post-operative complications were recorded. Intraocular pressure (IOP) measurements were recorded pre-operatively and repeated post-operatively on follow up days 1, 3, and 7, and months 1, 3, 6, 12, 18, and 24. Surgical success rates were recorded. Results: Mean pre-operative IOPs of groups A and B were 32.74 +/-+/- 11.25 and 34.29 +/-+/- 9.68 mmHg, respectively. In group A, anterior chamber bleeding (two cases), and choroidal detachment and/or ciliary detachment (four cases) occurred. In group B, anterior chamber bleeding (five cases), and choroidal detachment and/or ciliary detachment (11 cases) occurred. There was a statistically significant difference between the two groups. There also was statistically significant difference in post-operative IOPs between the two groups at 12 and 24 months. The surgical success rate of group A was higher than that of group B. Conclusion: ACM is effective in maintaining IOP and reducing complications during trabeculectomy following vitrectomy, thereby increasing surgical success rates. |
出版者 | INFORMA HEALTHCARE |
出版地 | LONDON |
ISSN | 0271-3683 |
EISSN | 1460-2202 |
卷号 | 36期号:3页码:232-237 |
DOI | 10.3109/02713683.2010.543498 |
页数 | 6 |
WOS类目 | Ophthalmology |
WOS研究方向 | Ophthalmology |
WOS记录号 | WOS:000287325700006 |
收录类别 | SCIE ; PUBMED ; SCOPUS |
URL | 查看原文 |
PubMed ID | 21275521 |
SCOPUSEID | 2-s2.0-79951843634 |
通讯作者地址 | [Wang, Yuhong]Hosp Eye, Dept Glaucoma, Wenzhou Med Coll, Wenzhou 325027, Peoples R China. |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/14422 |
专题 | 眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_青光眼专科 |
通讯作者 | Wang, Yuhong |
作者单位 | Hosp Eye, Dept Glaucoma, Wenzhou Med Coll, Wenzhou 325027, Peoples R China |
第一作者单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_青光眼专科 |
通讯作者单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_青光眼专科 |
第一作者的第一单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_青光眼专科 |
推荐引用方式 GB/T 7714 | Wang, Yuhong,Nie, Li. Use of the Anterior Chamber Maintainer in Trabeculectomy Following Vitrectomy[J]. CURRENT EYE RESEARCH,2011,36(3):232-237. |
APA | Wang, Yuhong, & Nie, Li. (2011). Use of the Anterior Chamber Maintainer in Trabeculectomy Following Vitrectomy. CURRENT EYE RESEARCH, 36(3), 232-237. |
MLA | Wang, Yuhong,et al."Use of the Anterior Chamber Maintainer in Trabeculectomy Following Vitrectomy".CURRENT EYE RESEARCH 36.3(2011):232-237. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
查看访问统计 |
谷歌学术 |
谷歌学术中相似的文章 |
[Wang, Yuhong]的文章 |
[Nie, Li]的文章 |
百度学术 |
百度学术中相似的文章 |
[Wang, Yuhong]的文章 |
[Nie, Li]的文章 |
必应学术 |
必应学术中相似的文章 |
[Wang, Yuhong]的文章 |
[Nie, Li]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论