题名Use of the Anterior Chamber Maintainer in Trabeculectomy Following Vitrectomy
作者
发表日期2011-03
发表期刊CURRENT EYE RESEARCH   影响因子和分区
语种英语
原始文献类型Article
关键词Anterior chamber maintainer Complications Intraocular pressure Trabeculectomy Vitrectomy
其他关键词AUTOMATED ENDOTHELIAL KERATOPLASTY ; INTRAOCULAR-LENS IMPLANTATION ; INCISION CATARACT-SURGERY ; VISCOELASTIC MATERIAL ; NUCLEUS MANAGEMENT ; PHACOEMULSIFICATION ; PRESSURE ; CAPSULE ; EYES
摘要Methods: Trabeculectomy was performed on 51 secondary glaucoma patients (51 eyes), all of whom had undergone vitrectomy. During trabeculectomy, an ACM was placed in 27 eyes (group A), but not in the remaining 24 (group B). Intra- and post-operative complications were recorded. Intraocular pressure (IOP) measurements were recorded pre-operatively and repeated post-operatively on follow up days 1, 3, and 7, and months 1, 3, 6, 12, 18, and 24. Surgical success rates were recorded. Results: Mean pre-operative IOPs of groups A and B were 32.74 +/-+/- 11.25 and 34.29 +/-+/- 9.68 mmHg, respectively. In group A, anterior chamber bleeding (two cases), and choroidal detachment and/or ciliary detachment (four cases) occurred. In group B, anterior chamber bleeding (five cases), and choroidal detachment and/or ciliary detachment (11 cases) occurred. There was a statistically significant difference between the two groups. There also was statistically significant difference in post-operative IOPs between the two groups at 12 and 24 months. The surgical success rate of group A was higher than that of group B. Conclusion: ACM is effective in maintaining IOP and reducing complications during trabeculectomy following vitrectomy, thereby increasing surgical success rates.
出版者INFORMA HEALTHCARE
出版地LONDON
ISSN0271-3683
EISSN1460-2202
卷号36期号:3页码:232-237
DOI10.3109/02713683.2010.543498
页数6
WOS类目Ophthalmology
WOS研究方向Ophthalmology
WOS记录号WOS:000287325700006
收录类别SCIE ; PUBMED ; SCOPUS
URL查看原文
PubMed ID21275521
SCOPUSEID2-s2.0-79951843634
通讯作者地址[Wang, Yuhong]Hosp Eye, Dept Glaucoma, Wenzhou Med Coll, Wenzhou 325027, Peoples R China.
引用统计
被引频次:21[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符https://kms.wmu.edu.cn/handle/3ETUA0LF/14422
专题眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_青光眼专科
通讯作者Wang, Yuhong
作者单位
Hosp Eye, Dept Glaucoma, Wenzhou Med Coll, Wenzhou 325027, Peoples R China
第一作者单位眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_青光眼专科
通讯作者单位眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_青光眼专科
第一作者的第一单位眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_青光眼专科
推荐引用方式
GB/T 7714
Wang, Yuhong,Nie, Li. Use of the Anterior Chamber Maintainer in Trabeculectomy Following Vitrectomy[J]. CURRENT EYE RESEARCH,2011,36(3):232-237.
APA Wang, Yuhong, & Nie, Li. (2011). Use of the Anterior Chamber Maintainer in Trabeculectomy Following Vitrectomy. CURRENT EYE RESEARCH, 36(3), 232-237.
MLA Wang, Yuhong,et al."Use of the Anterior Chamber Maintainer in Trabeculectomy Following Vitrectomy".CURRENT EYE RESEARCH 36.3(2011):232-237.

条目包含的文件

条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Wang, Yuhong]的文章
[Nie, Li]的文章
百度学术
百度学术中相似的文章
[Wang, Yuhong]的文章
[Nie, Li]的文章
必应学术
必应学术中相似的文章
[Wang, Yuhong]的文章
[Nie, Li]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。