题名 | Reliability research of multi-planar reformation of multi-spiral computerized tomography in measuring kyphosis angle after thoracolumbar fracture |
作者 | |
发表日期 | 2010-05-01 |
发表期刊 | Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Journal Article |
摘要 | Objective: To study the feasibility and reliability of the multi-planar reformation (MPR) of multi-spiral CT (MSCT) in measuring the kyphosis angle (KA) after thoracolumbar fracture. Methods From December 2007 to December 2009, 45 thoracolumbar fracture patients who underwent computed radiology (CR) and MSCT were recruited. There were 32 males and 13 females with a mean age of 48 years (range, 24-63 years), including 36 simple compression fractures and 9 burst fractures. The fracture locations were T11 in 6 cases, T12 in 11 cases, L1 in 20 cases, and L2 in 8 cases. Fracture was caused by traffic accident in 25 cases, by falling from height in 12 cases, and by others in 8 cases. The imaging examination was performed after 2 hours to 7 days of injury in 22 cases and after more than 7 days in 23 cases. The KA was measured on the lateral X-ray films of CR and MPR by two observers, then the measurements were done again after three weeks. The data were statistically analyzed. Results: The average KA values on CR by two observers were (20.75 +/- 8.31)degrees and (22.49 +/- 9.07)degrees, respectively; showing significant difference (P < 0.05), and the correlation was good (r = 0.882, P < 0.05). The average KA values on MPR by two observers were (16.65 +/- 8.62)degrees and (17.08 +/- 7.88)degrees, respectively, showing no significant difference (P > 0.05), the correlation was excellent (r = 0.976, P < 0.05). The average KA values on CR and MPR were (21.61 +/- 8.43)degrees and (16.87 +/- 8.20)degrees, respectively; showing significant difference (P < 0.05), the correlation was good (r = 0.852, P < 0.05). Conclusion: It is more feasible and reliable in measuring the KA on MRP of MSCT than CR, but the value is larger on CR. |
ISSN | 1002-1892 |
卷号 | 24期号:5页码:531-4. |
收录类别 | PUBMED |
URL | 查看原文 |
PubMed ID | 20540252 |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/63364 |
专题 | 附属第二医院_放射科 |
作者单位 | Department of Radiology, Affiliated No.2 Hospital of Wenzhou Medical College, Wenzhou Zhejiang 325027, PR China. |
第一作者单位 | 放射科 |
第一作者的第一单位 | 放射科 |
推荐引用方式 GB/T 7714 | Xubo Lin,Jiuzun Chen,Jiawei He,et al. Reliability research of multi-planar reformation of multi-spiral computerized tomography in measuring kyphosis angle after thoracolumbar fracture[J]. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery,2010,24(5):531-4.. |
APA | Xubo Lin, Jiuzun Chen, Jiawei He, Jianmin Cheng, Zhihan Yan, & Hui He. (2010). Reliability research of multi-planar reformation of multi-spiral computerized tomography in measuring kyphosis angle after thoracolumbar fracture. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 24(5), 531-4.. |
MLA | Xubo Lin,et al."Reliability research of multi-planar reformation of multi-spiral computerized tomography in measuring kyphosis angle after thoracolumbar fracture".Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery 24.5(2010):531-4.. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
查看访问统计 |
谷歌学术 |
谷歌学术中相似的文章 |
[Xubo Lin]的文章 |
[Jiuzun Chen]的文章 |
[Jiawei He]的文章 |
百度学术 |
百度学术中相似的文章 |
[Xubo Lin]的文章 |
[Jiuzun Chen]的文章 |
[Jiawei He]的文章 |
必应学术 |
必应学术中相似的文章 |
[Xubo Lin]的文章 |
[Jiuzun Chen]的文章 |
[Jiawei He]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论