题名 | Pulsed galvanostatic control of a solid-contact ion-selective electrode for potentiometric biosensing of microcystin-LR |
作者 | |
发表日期 | 2016-07 |
发表期刊 | SENSORS AND ACTUATORS B-CHEMICAL 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Article |
关键词 | Chronopotentiometry Solid-contact ion-selective electrodes Protein phosphatases Microcystin-LR |
其他关键词 | LABEL-FREE ; MEMBRANE ELECTRODES ; SENSITIVE DETECTION ; INHIBITION ASSAY ; ELECTROCHEMICAL DETECTION ; PROTEIN PHOSPHATASES ; ENZYME ; WATER ; QUANTIFICATION ; IMMUNOSENSOR |
摘要 | We report here on the development of a chronopotentiometric assay for microcystin-LR based on enzymatic inhibition. The inhibition of protein phosphatase by microcystin-LR can be sensed potentiometrically by using 4-nitrophenyl phosphate as an enzyme substrate. A solid-contact ion-selective electrode (ISE) with poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) as a transduction layer has been designed for potentiometric biosensing using the pulsed galvanastatic technique. By applying an anodic current, the enzymatic generated p-nitrophenol can be extracted into the polymeric membrane with tetradodecylammonium tetrakis(4-chlorophenyl)-borate to produce the chronopotentiometric signal. Meanwhile, a controlled voltage was applied to refresh the membrane for multiple consecutive measurements. The proposed potentiometric assay showed a linear response for microcystin-LR in the range 1-100 mu g/L with a detection limit of 0.5 mu g/L (3 sigma). We believe that the proposed method can be employed for sensitive, rapid and reliable determination of analytes involved in enzyme inhibition. (C) 2016 Elsevier B.V. All rights reserved. |
资助项目 | National Natural Science Foundation of ChinaNational Natural Science Foundation of China (NSFC) [21207156, 21575158, 41176081]; Youth Innovation Promotion Association of CAS [2013139]; Taishan Scholar Program of Shandong Province; Zhejiang Provincial Natural Science FoundationNatural Science Foundation of Zhejiang Province [LY14B070013]; Public Beneficial Project [2015C33306] |
出版者 | ELSEVIER SCIENCE SA |
出版地 | LAUSANNE |
ISSN | 0925-4005 |
卷号 | 230页码:785-790 |
DOI | 10.1016/j.snb.2016.02.121 |
页数 | 51 |
WOS类目 | Chemistry, Analytical ; Electrochemistry ; Instruments & Instrumentation |
WOS研究方向 | Chemistry ; Electrochemistry ; Instruments & Instrumentation |
WOS记录号 | WOS:000374329300100 |
收录类别 | SCIE ; EI ; SCOPUS |
EI入藏号 | 20161102083451 |
EI主题词 | Ion selective electrodes |
URL | 查看原文 |
SCOPUSEID | 2-s2.0-84960171661 |
通讯作者地址 | [Ding, Jiawang]Key Laboratory of Coastal Environmental Processes and Ecological Remediation,Yantai Institute of Coastal Zone Research (YIC),Chinese Academy of Sciences (CAS),Shandong Provincial Key Laboratory of Coastal Environmental Processes,YICCAS,Yantai,264003,China |
Scopus学科分类 | Electronic, Optical and Magnetic Materials;Instrumentation;Condensed Matter Physics;Surfaces, Coatings and Films;Metals and Alloys;Electrical and Electronic Engineering;Materials Chemistry |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/5470 |
专题 | 公共卫生学院_环境科学系 |
通讯作者 | Ding, Jiawang |
作者单位 | 1.Key Laboratory of Coastal Environmental Processes and Ecological Remediation,Yantai Institute of Coastal Zone Research (YIC),Chinese Academy of Sciences (CAS),Shandong Provincial Key Laboratory of Coastal Environmental Processes,YICCAS,Yantai,264003,China; 2.Department of Environmental Sciences,Key Laboratory of Watershed Science and Health of Zhejiang Province,Wenzhou Medical University,Wenzhou,325035,China |
第一作者单位 | 温州医科大学 |
推荐引用方式 GB/T 7714 | Yu, Nana,Ding, Jiawang,Wang, Wenwei,et al. Pulsed galvanostatic control of a solid-contact ion-selective electrode for potentiometric biosensing of microcystin-LR[J]. SENSORS AND ACTUATORS B-CHEMICAL,2016,230:785-790. |
APA | Yu, Nana, Ding, Jiawang, Wang, Wenwei, Wang, Xuedong, & Qin, Wei. (2016). Pulsed galvanostatic control of a solid-contact ion-selective electrode for potentiometric biosensing of microcystin-LR. SENSORS AND ACTUATORS B-CHEMICAL, 230, 785-790. |
MLA | Yu, Nana,et al."Pulsed galvanostatic control of a solid-contact ion-selective electrode for potentiometric biosensing of microcystin-LR".SENSORS AND ACTUATORS B-CHEMICAL 230(2016):785-790. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论