摘要目的:评价锥形束CT(cone-beam CT,CBCT)对下颌前磨牙髓腔三维重建的精度。方法:选取32颗单根下颌前磨牙,分别采用显微CT(micro-CT)和CBCT进行扫描,对髓腔进行三维重建,分别提取髓腔的三维表面模型和三维体积模型。在Amira5.0软件中对髓腔表面模型配准后,以micro-CT重建的髓腔模型为参考,检测CBCT重建模型和其相比的形态差异,进行色阶图颜色标示,记录整体形态的三维偏差值并分析2种扫描图像对髓腔体积重建的测量值差异。采用SPSS13.0软件包对数据进行统计学分析。结果:32颗牙的三维形态偏差RSM值平均为0.27mm,最大的形态差异分布于髓腔的根尖段和一些细小的解剖变异结构。Micro-CT和CBCT重建髓腔模型的体积测量值分别为(34.89±4.36)mm~3和(27.32±4.83)mm~3,差异具有显著性(P<0.05)。结论:利用CBCT扫描图像对下颌前磨牙髓腔进行三维重建时,存在着一定程度的结构丢失,且多位于根尖段和细小的解剖变异部位。口腔临床医师在利用CBCT辅助诊疗时,应考虑到以上特点。
其他摘要PURPOSE: To analyze the accuracy of 3D reconstruction of pulp cavity in mandibular premolars based on cone-beam CT (CBCT). METHODS: Thirty-two extracted single-rooted mandibular premolars were randomly collected and scanned by micro-CT and CBCT. After image segmentation and 3D reconstruction, the surface model and volume model of the pulp cavity were rendered. By using Amira 5.0 software, each pairs of pulp cavity surface models were registered. The surface models reconstructed from micro-CT scanning were set as the references and the surface models reconstructed from CBCT were tested. The morphological differences between each pairs of surface models were calculated by Amira 5.0 software and represented by color-coded maps. The total 3D morphological difference value of each sample was recorded and the volume reconstruction differences between the two image acquisition techniques were analyzed. Statistical analysis was performed with SPSS 13.0 software package. RESULTS: The mean value of 3D morphological differences of 32 teeth was 0.27 mm. Distribution of the greatest morphological differences were mainly located in the apical portion of the pulp cavity and some small anatomical variation. The volume of the reconstructed models by micro-CT and CBCT were (34.89±4.36) mm~3 and (27.32±4.83) mm~3 respectively, and the difference was significant (P<0.05). CONCLUSIONS: When CBCT scanning is used to reconstruct pulp cavity of mandibular premolars, there is certain degree of information loss, which mainly distributes in the apical portion and small anatomical variation sites. Dentists should consider these characteristics during clinical application of CBCT.
资助项目温州市科技计划项目(Y20140333)
ISSN1006-7248
卷号27期号:02页码:146-149
DOI10.19439/j.sjos.2018.02.007
页数4
收录类别CNKI ; 万方 ; 维普 ; 北大核心 ; PKU ; CSCD ; ISTIC
学科领域医药、卫生 ; 口腔科学
URL查看原文
CSCD记录号CSCD:6235374
引用统计
文献类型期刊论文
条目标识符https://kms.wmu.edu.cn/handle/3ETUA0LF/47176
专题口腔医学院、附属口腔医院
口腔医学院、附属口腔医院_儿童口腔
作者单位
1.温州医科大学附属口腔医院牙体牙髓病科;
2.温州医科大学附属口腔医院儿童口腔科
第一作者单位口腔医学院、附属口腔医院
第一作者的第一单位口腔医学院、附属口腔医院
推荐引用方式
GB/T 7714
李骏,潘乙怀,赵瑜,等. 锥形束CT对下颌前磨牙髓腔三维重建的精度分析[J]. 上海口腔医学,2018,27(02):146-149.
APA 李骏, 潘乙怀, 赵瑜, & 李玲. (2018). 锥形束CT对下颌前磨牙髓腔三维重建的精度分析. 上海口腔医学, 27(02), 146-149.
MLA 李骏,et al."锥形束CT对下颌前磨牙髓腔三维重建的精度分析".上海口腔医学 27.02(2018):146-149.

条目包含的文件

下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
SHKY201802011.CAJ(2362KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[李骏]的文章
[潘乙怀]的文章
[赵瑜]的文章
百度学术
百度学术中相似的文章
[李骏]的文章
[潘乙怀]的文章
[赵瑜]的文章
必应学术
必应学术中相似的文章
[李骏]的文章
[潘乙怀]的文章
[赵瑜]的文章
相关权益政策
暂无数据
收藏/分享
文件名: SHKY201802011.CAJ
格式: CAJ VIEWER
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。