科研成果详情

题名Comparison of the biomechanical stability of cannulated screw and reconstruction plate for the fixation of symphysis pubis diastasis
作者
发表日期2010-12-01
发表期刊Yiyong Shengwu Lixue/Journal of Medical Biomechanics   影响因子和分区
语种中文
原始文献类型Journal article (JA)
关键词Biomechanics Convergence of numerical methods Ligaments Mechanical testing Stability Biomechanical properties Biomechanical stability Cannulated screws Clinical practices Reconstruction plates Sacroiliac joints Standing posture Sympysis pubis diastasis
摘要ObjectiveTo test the biomechanical properties of symphysis pubis diastasis fixed by cannulated screw or reconstruction plate and provide the theoretical basis for clinical practice. MethodIn the experiment, fifteen normal adult specimens' pelvis along with their intact spines from L5 to the proximal 2/3 of both femora were randomly divided into three groups. The symphysis pubis, unilateral anterior sacroiliac joint and ipsilateral sacropinous and sacrotuberous ligaments were cut; the intact major pelvic ligaments and hip joints were used to simulate Tile B1 pelvic fracture model. The fixation of five-hole reconstruction plate and 6.5 mm cannulated screw were applied successively to cure symphysis pubis diastasis. The pelves were loaded vertically in the testing machine with a standing posture. The loads were applied through the L5 body to a maximum of approximately 400 N, while the displacements of the symphysis pubis were recorded. ResultsThe study showed that two fixations were able to reduce symphysis pubis gapping and restore the biomechanical stability of pelves. Under the same condition, the displacement of symphysis pubis used 3.5 mm five-hole reconstruction plate with 4 cortical screws, and the displacement by using cannulated screw were (0.944±0.983) mm and (-0.03±0.378) mm respectively. There were significant differences (P
出版者Shanghai Jiaotong University School of Medicine
ISSN1004-7220
卷号25期号:6页码:475-478
收录类别EI
EI入藏号20110613656371
EI主题词Screws
文献类型期刊论文
条目标识符https://kms.wmu.edu.cn/handle/3ETUA0LF/35024
专题第二临床医学院,附属第二医院、育英儿童医院
附属第二医院
作者单位
Department of Orthopaedic Surgery, The Second Affiliated Hospital of Wenzhou Medical College, Wenzhou 325100, Zhejiang, China
第一作者单位第二临床医学院,附属第二医院、育英儿童医院;  附属第二医院
第一作者的第一单位第二临床医学院,附属第二医院、育英儿童医院;  附属第二医院
推荐引用方式
GB/T 7714
Yu, Ke-He,Hong, Jian-Jun,Chen, Lin-Wei,et al. Comparison of the biomechanical stability of cannulated screw and reconstruction plate for the fixation of symphysis pubis diastasis[J]. Yiyong Shengwu Lixue/Journal of Medical Biomechanics,2010,25(6):475-478.
APA Yu, Ke-He, Hong, Jian-Jun, Chen, Lin-Wei, & Guo, Xiao-Shan. (2010). Comparison of the biomechanical stability of cannulated screw and reconstruction plate for the fixation of symphysis pubis diastasis. Yiyong Shengwu Lixue/Journal of Medical Biomechanics, 25(6), 475-478.
MLA Yu, Ke-He,et al."Comparison of the biomechanical stability of cannulated screw and reconstruction plate for the fixation of symphysis pubis diastasis".Yiyong Shengwu Lixue/Journal of Medical Biomechanics 25.6(2010):475-478.

条目包含的文件

条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Yu, Ke-He]的文章
[Hong, Jian-Jun]的文章
[Chen, Lin-Wei]的文章
百度学术
百度学术中相似的文章
[Yu, Ke-He]的文章
[Hong, Jian-Jun]的文章
[Chen, Lin-Wei]的文章
必应学术
必应学术中相似的文章
[Yu, Ke-He]的文章
[Hong, Jian-Jun]的文章
[Chen, Lin-Wei]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。