摘要 | PURPOSE: To evaluate the influence of a capsular tension ring (CTR) on the intraocular lens (IOL)-capsule complex after cataract surgery in patients with long axial length. METHODS: This was a prospective study. Patients underwent phacoemulsification and IOL implantation, with or without CTR implantation. Swept-source optical coherence tomography was performed at 1 day, 1 week, 1 month, and 3 months postoperatively to determine the postoperative aqueous depth (PAD), capsular bend index (CBI), and IOL tilt and decentration. Spherical equivalent values were obtained through subjective refraction and autorefraction. Root mean square was adopted to evaluate the indices listed above. RESULTS: Forty-three patients (56 eyes) were included in the study. Generalized estimating equation analysis of PAD showed a statistical difference between groups (P P = .031). The RMS of the change in PAD was smaller in the CTR group than in the non-CTR group during the 3 months after surgery (P P = .015). CBI in the CTR group increased more from 1 to 3 months after surgery than that in the non-CTR group (P P = .025). The RMS of the change in vertical decentration was smaller in the CTR group than in the non-CTR group during the 3-month follow-up (P P = .009). CONCLUSIONS: CTR implantation can stabilize the axial position of the IOL within the capsular bag after cataract surgery in patients with long axial length without affecting the refractive stability. The formation of capsular bend may be slightly delayed in the early stage after CTR implantation, but it accelerates from 1 to 3 months after surgery. |
出版者 | SLACK INC |
ISSN | 1081-597X |
EISSN | 1938-2391 |
卷号 | 40期号:9页码:e654-e661 |
DOI | 10.3928/1081597X-20240723-02 |
页数 | 8 |
WOS类目 | Ophthalmology ; Surgery |
WOS研究方向 | Ophthalmology ; Surgery |
WOS记录号 | WOS:001319488800008 |
收录类别 | SCIE ; SCOPUS |
URL | 查看原文 |
PubMed ID | 39254247 |
SCOPUSEID | 2-s2.0-85203760776 |
通讯作者地址 | [Zhao, Yune]Wenzhou Med Univ Hangzhou, Eye Hosp, 618 East Fengqi Rd, Hangzhou 310000, Zhejiang, Peoples R China. |
Scopus学科分类 | Surgery;Ophthalmology |
SCOPUS_ID | SCOPUS_ID:85203760776 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/220684 |
专题 | 眼视光学院(生物医学工程学院)、附属眼视光医院 眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区 |
通讯作者 | Zhao, Yune |
作者单位 | 1.Wenzhou Med Univ, Eye Hosp, Sch Ophthalmol & Optometry, Wenzhou, Peoples R China; 2.Wenzhou Med Univ, Eye Hosp, Natl Clin Res Ctr Ocular Dis, Wenzhou, Peoples R China; 3.Wenzhou Med Univ, Eye Hosp, Hangzhou Branch, Hangzhou, Peoples R China; 4.Ningbo Univ, Affiliated Hosp 1, Ningbo, Peoples R China |
第一作者单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院; 杭州院区 |
通讯作者单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院 |
第一作者的第一单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院 |
推荐引用方式 GB/T 7714 | Chang, Pingjun,Hu, Yiwen,Wu, Xueer,et al. Influence of Capsular Tension Rings on the IOL-Capsule Complex in Patients With Long Axial Length: A Clinical Observation Based on SS-OCT[J]. Journal of Refractive Surgery,2024,40(9):e654-e661. |
APA | Chang, Pingjun., Hu, Yiwen., Wu, Xueer., Qian, Shuyi., Li, Yuanyuan., ... & Zhao, Yune. (2024). Influence of Capsular Tension Rings on the IOL-Capsule Complex in Patients With Long Axial Length: A Clinical Observation Based on SS-OCT. Journal of Refractive Surgery, 40(9), e654-e661. |
MLA | Chang, Pingjun,et al."Influence of Capsular Tension Rings on the IOL-Capsule Complex in Patients With Long Axial Length: A Clinical Observation Based on SS-OCT".Journal of Refractive Surgery 40.9(2024):e654-e661. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论