题名 | The corneal biomechanical differences after wearing orthokeratology lenses and multifocal soft lenses in children: A self-control study |
作者 | |
发表日期 | 2024-02 |
发表期刊 | CONTACT LENS & ANTERIOR EYE 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Article ; Journal Article |
关键词 | Orthokeratology lens Defocus Incorporated Soft Contact lens Myopia progression Corneal biomechanical features |
其他关键词 | SHORT-TERM ; MYOPIA ; PROGRESSION ; PREVALENCE |
摘要 | Background: To compare the changes in corneal biomechanics after orthokeratology (OK) lens and Defocus Incorporated Soft Contact (DISC) lens treatment. Methods: Of 28 myopic children were recruited, with one eye wearing OK lens and the other eye wearing DISC lens for one year, and the data after discontinued for 4 weeks were also collected. Major outcomes were corneal biomechanics and axial length (AL) elongation. Results: Throughout the follow-up period, the DISC group had longer the first applanation (A1) time, larger A1 deformation amplitude, A1 deflection length (A1 DLL), and A1 deflection amplitude than the OK group. AL elongation was less in the OK group at each visit (all P < 0.05) but faster in the OK group than in the DISC group after discontinuation (P = 0.006). Moreover, AL elongation was related to baseline A1 time, A1 velocity and whole eye movement max in the DISC group, and in the OK group, was related to the baseline the second applanation (A2) DLL, A2 delta arc length and stiffness parameter A1 (all P < 0.05). Conclusions: The cornea was more deformable after wearing DISC lens than OK lens, and corneal biomechanical parameters were associated with AL elongation. Eyes showed less AL elongation during OK lens treatment while faster AL elongation after discontinuation than DISC lens. The baseline corneal biomechanics may help to predict AL elongation in myopic control strategies. |
资助项目 | National Natural Science Foundation of China Youth Science Foundation Project [82201176]; Science and Technology Program of Wenzhou City [Y20220146]; Medical and Health of Zhejiang Province [2023KY153] |
出版者 | ELSEVIER |
ISSN | 1367-0484 |
EISSN | 1476-5411 |
卷号 | 47期号:1 |
DOI | 10.1016/j.clae.2023.102089 |
页数 | 8 |
WOS类目 | Ophthalmology |
WOS研究方向 | Ophthalmology |
WOS记录号 | WOS:001168996200001 |
收录类别 | SCIE ; PUBMED ; SCOPUS |
在线发表日期 | 2024-01 |
URL | 查看原文 |
PubMed ID | 37951739 |
SCOPUSEID | 2-s2.0-85176420842 |
通讯作者地址 | [Li, Zhangliang]School of Ophthalmology and Optometry,Wenzhou Medical University,Zhejiang,Hangzhou,China |
Scopus学科分类 | Ophthalmology;Optometry |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/209922 |
专题 | 眼视光学院(生物医学工程学院)、附属眼视光医院 |
通讯作者 | Li, Zhangliang |
作者单位 | National Clinical Research Center for Ocular Diseases,Eye Hospital,Wenzhou Medical University,Wenzhou,China |
第一作者单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院 |
第一作者的第一单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院 |
推荐引用方式 GB/T 7714 | Fu, Lin,Jiang, Yi,Lian, Hengli,et al. The corneal biomechanical differences after wearing orthokeratology lenses and multifocal soft lenses in children: A self-control study[J]. CONTACT LENS & ANTERIOR EYE,2024,47(1). |
APA | Fu, Lin., Jiang, Yi., Lian, Hengli., Lou, Jiangtao., Chen, Ruru., ... & Zhang, Yunjie. (2024). The corneal biomechanical differences after wearing orthokeratology lenses and multifocal soft lenses in children: A self-control study. CONTACT LENS & ANTERIOR EYE, 47(1). |
MLA | Fu, Lin,et al."The corneal biomechanical differences after wearing orthokeratology lenses and multifocal soft lenses in children: A self-control study".CONTACT LENS & ANTERIOR EYE 47.1(2024). |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
查看访问统计 |
谷歌学术 |
谷歌学术中相似的文章 |
[Fu, Lin]的文章 |
[Jiang, Yi]的文章 |
[Lian, Hengli]的文章 |
百度学术 |
百度学术中相似的文章 |
[Fu, Lin]的文章 |
[Jiang, Yi]的文章 |
[Lian, Hengli]的文章 |
必应学术 |
必应学术中相似的文章 |
[Fu, Lin]的文章 |
[Jiang, Yi]的文章 |
[Lian, Hengli]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论