题名 | What is the stable internal fixation for the unstable and osteoporotic supracondylar femoral fractures: a finite element analysis |
作者 | |
发表日期 | 2023-10-07 |
发表期刊 | Journal of orthopaedic surgery and research 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Journal Article |
关键词 | BLLP Biomechanical study ULLP UOSFF |
其他关键词 | DISTAL FEMUR FRACTURES ; SLIDING HIP SCREW ; STABILIZATION ; LOCKING ; POSITION ; PLATE |
摘要 | Osteoporotic supracondylar femoral fractures (OSFF) have historically been managed by the lateral anatomical locking plate with reasonable success. However, for some kinds of unstable and osteoporotic supracondylar femoral fractures (UOSFF), especially with bone defects, unilateral locking plate (ULLP) fixation failed or resulted in implant breakage. This paper is going to explore what is the stable internal fixation for UOSFF by adding the bilateral locking plate (BLLP) fixation., OSFF models were divided into two groups according to the fracture line type, which would be further subdivided according to their angle of fracture line, presence of bone defect, location, and degree of bone defect. Thereafter, kinds of locking plate fixation were constructed. A 2010-N load was applied to the femoral head, and a 1086-N load was applied to the greater trochanter. In this condition, the maximum von Mises stress distribution of models were investigated., Firstly, it was obviously found that the stress concentration in the BLLP group was more dispersed than that in the ULLP group. Secondly, according to the fracture line analysis, the stress value of fracture line type in "\" model group was higher than that of "/" model group. Moreover, with the increase in fracture line angle, the stress value of the model increased. Thirdly, from the bone defect analysis, the stress value of the medial bone defect (MBD) model group was higher than that of the lateral bone defect (LBD) model group. And as the degree of bone defect increased, the stress value increased gradually in the model group., In the following four cases, lateral unilateral locking plate fixation cannot effectively stabilize the fracture end, and double locking plate internal fixation is a necessary choice. First, when the angle of the fracture line is large (30, 45). Second, when the fracture line type is "/." Third, when the bone defect is large. Fourth, when the bone defect is medial. |
出版者 | BMC |
ISSN | 1749-799X |
卷号 | 18期号:1 |
DOI | 10.1186/s13018-023-04256-9 |
页数 | 11 |
WOS类目 | Orthopedics |
WOS研究方向 | Orthopedics |
WOS记录号 | WOS:001080400100002 |
收录类别 | PUBMED ; SCIE ; SCOPUS |
URL | 查看原文 |
PubMed ID | 37805559 |
SCOPUSEID | 2-s2.0-85173505206 |
通讯作者地址 | [Xu, Jiangbao]The Quzhou Affiliated Hospital of Wenzhou Medical University,Quzhou,People’s Hospital,Quzhou,324000,China |
Scopus学科分类 | Surgery;Orthopedics and Sports Medicine |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/183341 |
专题 | 其他_温州医科大学附属衢州医院 |
通讯作者 | Xu, Jiangbao |
作者单位 | 1.The Quzhou Affiliated Hospital of Wenzhou Medical University,Quzhou,People’s Hospital,Quzhou,324000,China; 2.Jiangshan People’s Hospital,Jiangshan,324100,China |
通讯作者单位 | 其他_温州医科大学附属衢州医院 |
推荐引用方式 GB/T 7714 | Rao, Jianwei,Zhang, Junchao,Ye, Zhou,et al. What is the stable internal fixation for the unstable and osteoporotic supracondylar femoral fractures: a finite element analysis[J]. Journal of orthopaedic surgery and research,2023,18(1). |
APA | Rao, Jianwei, Zhang, Junchao, Ye, Zhou, Zhang, Liguang, & Xu, Jiangbao. (2023). What is the stable internal fixation for the unstable and osteoporotic supracondylar femoral fractures: a finite element analysis. Journal of orthopaedic surgery and research, 18(1). |
MLA | Rao, Jianwei,et al."What is the stable internal fixation for the unstable and osteoporotic supracondylar femoral fractures: a finite element analysis".Journal of orthopaedic surgery and research 18.1(2023). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论