题名 | Safety and efficacy of cataract surgery performed with a low-energy femtosecond laser compared with conventional phacoemulsification in Chinese patients: a randomized clinical trial |
作者 | |
发表日期 | 2023-07-02 |
发表期刊 | EYE AND VISION 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Journal Article |
关键词 | Cataract surgery FEMTO LDV Z8 FLACS versus manual Femtosecond laser-assisted cataract surgery Low-energy FLACS |
其他关键词 | ENDOTHELIAL-CELL LOSS ; CORNEAL THICKNESS ; FRAGMENTATION ; TIME ; CAPSULOTOMY |
摘要 | To compare the safety and efficacy of femtosecond laser-assisted cataract surgery (FLACS) performed with the low-energy FEMTO LDV Z8 (Ziemer Ophthalmic Systems AG, Port, Switzerland) laser compared with conventional phacoemulsification (CP) in Chinese patients., This prospective, multicenter, interventional study included 126 patients who were randomized (1:1) to undergo either FLACS or CP followed by intraocular lens (IOL) implantation between January 2019 and April 2020. The primary endpoint included the comparison of the endothelial cell loss (ECL) between the two groups at 3 months. Secondary endpoints included the comparison of cumulative dissipated energy (CDE), change in central corneal thickness (CCT) from baseline, and postoperative uncorrected and corrected distance visual acuities (UDVA and CDVA) in the two groups., {AbstractText=At all postoperative time points, the FLACS group was found to be non-inferior to CP for the mean ECL (- 409.3 versus - 436.9 cells/mm2 at 3 months) and mean CDE (4.1 versus 4.5 percent-seconds). The increase in CCT was significantly lower in the FLACS group compared with the CP group at Day 7 (4.9 versus 9.2 µm; P = 0.04); however, the difference was not statistically significant at 1 and 3 months. Postoperatively, mean UDVA and CDVA were comparable between the two groups. No intraoperative complications occurred.}, Cataract surgery performed with a low-energy femtosecond laser was non-inferior to CP; however, the FLACS group had a statistically significantly lower increase in CCT at Day 7 compared with CP. Trial registration This trial is registered at ClinicalTrials.gov on May 15, 2019, with trial registration number: NCT03953053. |
出版者 | BMC |
ISSN | 2326-0254 |
卷号 | 10期号:1 |
DOI | 10.1186/s40662-023-00347-0 |
页数 | 9 |
WOS类目 | Ophthalmology |
WOS研究方向 | Ophthalmology |
WOS记录号 | WOS:001020896600001 |
收录类别 | SCIE ; PUBMED ; SCOPUS |
URL | 查看原文 |
PubMed ID | 37393278 |
SCOPUSEID | 2-s2.0-85163834517 |
通讯作者地址 | [Yu, A-Yong]National Clinical Research Center for Ocular Diseases,Eye Hospital,Wenzhou Medical University,270 West Xueyuan Road, Zhejiang,Wenzhou,325000,China |
Scopus学科分类 | Health Professions (miscellaneous);Ophthalmology |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/181271 |
专题 | 眼视光学院(生物医学工程学院)、附属眼视光医院 眼视光学院(生物医学工程学院)、附属眼视光医院_白内障中心 |
通讯作者 | Yu, A-Yong |
作者单位 | 1.National Clinical Research Center for Ocular Diseases,Eye Hospital,Wenzhou Medical University,270 West Xueyuan Road, Zhejiang,Wenzhou,325000,China; 2.Qingdao Eye Hospital of Shandong First Medical University,Shandong,China; 3.Aier Eye Hospital of Wuhan University,Wuhan,China |
第一作者单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院 |
通讯作者单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院 |
第一作者的第一单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院 |
推荐引用方式 GB/T 7714 | Zhou, Kai-Jing,Huang, Yusen,Wang, Yong,et al. Safety and efficacy of cataract surgery performed with a low-energy femtosecond laser compared with conventional phacoemulsification in Chinese patients: a randomized clinical trial[J]. EYE AND VISION,2023,10(1). |
APA | Zhou, Kai-Jing., Huang, Yusen., Wang, Yong., Pan, An-Peng., Shao, Xu., ... & Yu, A-Yong. (2023). Safety and efficacy of cataract surgery performed with a low-energy femtosecond laser compared with conventional phacoemulsification in Chinese patients: a randomized clinical trial. EYE AND VISION, 10(1). |
MLA | Zhou, Kai-Jing,et al."Safety and efficacy of cataract surgery performed with a low-energy femtosecond laser compared with conventional phacoemulsification in Chinese patients: a randomized clinical trial".EYE AND VISION 10.1(2023). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论