科研成果详情

题名Influence of different implant designs on replacement of four teeth of the posterior free-end edentulism: Three-dimensional finite element analysis and clinic case validation
作者
发表日期2023-08
发表期刊Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft   影响因子和分区
语种英语
原始文献类型Journal Article
关键词Finite element analysis Implants Mandible Prosthetic dentistry Stress
其他关键词FIXED DENTAL PROSTHESES ; STRESS-DISTRIBUTION ; BONE ; NUMBER ; DENTISTRY ; DIAMETER ; SURVIVAL
摘要With periodontal disease having an increasing incidence, mandibular free-end edentulism caused by periodontitis is clinically more common. Finite element analysis and clinical case reports were used to evaluate the influence of different designs on the load distribution of implant prosthesis in mandibular posterior free-end edentulism., A finite element model of a mandible with posterior free-end edentulism was established. Considering the implant position and selection of single crown repair or splint repair, four designs were conducted including model A: 3435 × 37(four-unit fixed bridge supported by three implants, implant positions were 34, 35, 37); model B: 34,35 × 37, (34: a single implant crown) (35 ×37: three-unit fixed bridge supported by two implants, implant positions were 35, 37); model C: 34 × 3637(four-unit fixed bridge supported by three implants, implant positions were 34, 36, 37); and model D: 34 × 36, 37(37: a single implant crown)(34 ×36: three-unit fixed bridge supported by two implants, implant positions were 34, 36). Stress distribution and the Von Mises stress value of the implants, the crown and the bone around the implants were analyzed at vertical and 45° inclined load., Stress in the cortical bone was mainly concentrated around the implant neck, and maximum Von Mises stress (MVMS) of the four models was 11.6-16.1 MPa at vertical load and 61.74-96.49 MPa at 45° inclined load. Stress in the cancellous bone was concentrated around the implant base, and MVMS of four models was 3.075-3.899 MPa at vertical load and 5.021-6.165 MPa at 45° inclined load. Stress of the restoration crowns was mainly concentrated in the connector of the bridge, and MVMS of four models was 23.38-26.28 MPa at vertical load and 53.14-56.35 MPa at 45° inclined load. Stress of the implant interface was mainly concentrated on the surface of the smaller implants near the bridge, and MVMS of four models was 21.12-33.25 MPa at vertical load and 83.73-138.7 MPa at 45° inclined load., There was favorable stress distribution of the four models at vertical load and 45° inclined load. Design of a three-unit fixed bridge combined with a partial crown may be an available option for devising patient treatment plans with mandibular free-end edentulism.
资助项目Wenzhou Municipal Science and Technology Bureau Projects, China [Y20220378, ZY2022022]; Wenzhou Major Scientific and Technological Innovation Project [81271663]; National Natural Science Foundation of China [31471146, QTJ06012]; Wenzhou Medical University Scientific Development Foundation of Zhejiang, China [2022R413A044]; Zhejiang Province Science and Technology Plan Research and Xinmiao Talent Program, China; [Y2020594]
出版者ELSEVIER GMBH
ISSN0940-9602
EISSN1618-0402
卷号249
DOI10.1016/j.aanat.2023.152111
页数8
WOS类目Anatomy & Morphology
WOS研究方向Anatomy & Morphology
WOS记录号WOS:001056662900001
收录类别PUBMED ; SCIE ; SCOPUS
在线发表日期2023-06
URL查看原文
PubMed ID37247761
SCOPUSEID2-s2.0-85160807366
通讯作者地址[Ding, Xi]Department of Stomatology,The First Affiliated Hospital of Wenzhou Medical University,Zhejiang,Wenzhou,325015,China
Scopus学科分类Anatomy;Developmental Biology
引用统计
文献类型期刊论文
条目标识符https://kms.wmu.edu.cn/handle/3ETUA0LF/180602
专题其他_附属平阳医院(平阳县人民医院)
附属第一医院
数字化医学与智能技术研究院
通讯作者Ding, Xi
作者单位
1.Department of Stomatology,Pingyang Hospital Affiliated of Wenzhou Medical University(The People's Hospital of Pingyang),Zhejiang,Wenzhou,325400,China;
2.Institute of Digitized Medicine and Intelligent Technology,Wenzhou Medical University,Zhejiang,Wenzhou,325015,China;
3.Department of Stomatology,The First Affiliated Hospital of Wenzhou Medical University,Zhejiang,Wenzhou,325015,China
第一作者单位其他_附属平阳医院(平阳县人民医院);  数字化医学与智能技术研究院
通讯作者单位附属第一医院
第一作者的第一单位其他_附属平阳医院(平阳县人民医院)
推荐引用方式
GB/T 7714
Ye, Zhangyan,Ye, Hao,Jiang, Zhengting,et al. Influence of different implant designs on replacement of four teeth of the posterior free-end edentulism: Three-dimensional finite element analysis and clinic case validation[J]. Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft,2023,249.
APA Ye, Zhangyan., Ye, Hao., Jiang, Zhengting., Wu, Suwen., Feng, Zhongqiang., ... & Wu, Lijun. (2023). Influence of different implant designs on replacement of four teeth of the posterior free-end edentulism: Three-dimensional finite element analysis and clinic case validation. Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft, 249.
MLA Ye, Zhangyan,et al."Influence of different implant designs on replacement of four teeth of the posterior free-end edentulism: Three-dimensional finite element analysis and clinic case validation".Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft 249(2023).

条目包含的文件

条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Ye, Zhangyan]的文章
[Ye, Hao]的文章
[Jiang, Zhengting]的文章
百度学术
百度学术中相似的文章
[Ye, Zhangyan]的文章
[Ye, Hao]的文章
[Jiang, Zhengting]的文章
必应学术
必应学术中相似的文章
[Ye, Zhangyan]的文章
[Ye, Hao]的文章
[Jiang, Zhengting]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。