题名 | Anatomical and Biomechanical Stability of Single/Double Screw-Cancellous Bone Fixations of Regan-Morry Type III Ulnar Coronoid Fractures in Adults: CT Measurement and Finite Element Analysis |
作者 | |
发表日期 | 2023-04 |
发表期刊 | Orthopaedic surgery 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Journal Article |
关键词 | Anatomical and Biomechanical Stability Digital Orthopaedics Surgery Finite Element Method Smart Screw Internal Fixation Ulnar Coronoid Fracture |
其他关键词 | PULLOUT STRENGTH ; RADIAL HEAD ; ELBOW |
摘要 | At present, it is still uncertain whether single screw has the same stability as double screws in the treatment of ulnar coronal process basal fracture (Regan-Morry type III). So, we aimed to compare the pull-out force and anti-rotation torque of anterior single/double screw-cancellous bone fixation (aSSBF, aDSBF) in this fracture, and further study the influencing factors on anatomical and biomechanical stability of smart screw internal fixations., A total of 63 adult volunteers with no history of elbow injury underwent elbow CT scanning with associated three-dimensional reconstruction that enabled the measurements of bone density and fixed length of the proximal ulna and coronoid. The models of coronal process basal fracture, aSSBF and aDSBF, were developed and validated. Using the finite element model test, the sensitivity analysis of pull-out force and rotational torque was carried out., The pull-out force of aSSBF model was positively correlated with the density of the cancellous bone and linearly related to the fixed depth of the screw. The load pattern of pull-out force of aDSBF model was similar to that of aSSBF model. The ultimate torque of aDSBF model was higher than that of aSSBF model, but the load pattern of ultimate torque of both models was similar to each other when the fracture reset was satisfactory, and the screw nut attaches closely to coronoid process. Moreover, with enhancement of initial pre-tightening force, the increase of ultimate torque of both models was small., In addition to three pull-out stability factors of smart screw fixations, fracture surface fitting degree and nut fitting degree are the other two important anatomical and biomechanical stability factors of smart screw fixations both for rotational stability. When all pull-out stability and rotational stability factors meet reasonable conditions simultaneously, single or double screw fixation methods are stable for the treatments of ulnar coronoid basal fractures. |
资助项目 | National Natural Science Foundation of China [81271663, 31471146]; Wenzhou Medical University Scientific Development Foundation of Zhejiang, China [QTJ06012]; Basic Scientific Research Project of Wenzhou City of China [Y20210398]; Zhejiang Province Science and Technology Plan Research and Xinmiao Talent Program, China [2021R413036] |
出版者 | WILEY |
ISSN | 1757-7853 |
EISSN | 1757-7861 |
卷号 | 15期号:4页码:1072-1084 |
DOI | 10.1111/os.13664 |
页数 | 13 |
WOS类目 | Orthopedics |
WOS研究方向 | Orthopedics |
WOS记录号 | WOS:000916847200001 |
收录类别 | PUBMED ; SCIE ; SCOPUS |
在线发表日期 | 2023-01 |
URL | 查看原文 |
PubMed ID | 36647280 |
SCOPUSEID | 2-s2.0-85146656692 |
通讯作者地址 | [Wu, Lijun]Institute of Digitized Medicine and Intelligent Technology,Wenzhou Medical University,Zhejiang,325000,China |
Scopus学科分类 | Surgery;Orthopedics and Sports Medicine |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/172435 |
专题 | 数字化医学与智能技术研究院 附属第二医院 其他_附属第三医院(瑞安市人民医院) |
通讯作者 | Wu, Lijun |
作者单位 | 1.Institute of Digitized Medicine and Intelligent Technology,Wenzhou Medical University,Wenzhou,China; 2.Department of Orthopedics,Tianjin Teda Hospital,Tianjin,China; 3.Department of Orthopedics,The Third Affiliated Hospital,Wenzhou Medical University,Wenzhou,China; 4.Department of Orthopedics,The Second Affiliated Hospital,Wenzhou Medical University,Wenzhou,China |
第一作者单位 | 数字化医学与智能技术研究院 |
通讯作者单位 | 数字化医学与智能技术研究院 |
第一作者的第一单位 | 数字化医学与智能技术研究院 |
推荐引用方式 GB/T 7714 | Ye, Hao,Yang, Yongchao,Xing, Tingyang,et al. Anatomical and Biomechanical Stability of Single/Double Screw-Cancellous Bone Fixations of Regan-Morry Type III Ulnar Coronoid Fractures in Adults: CT Measurement and Finite Element Analysis[J]. Orthopaedic surgery,2023,15(4):1072-1084. |
APA | Ye, Hao., Yang, Yongchao., Xing, Tingyang., Tan, Guirong., Jin, Shuxun., ... & Wu, Lijun. (2023). Anatomical and Biomechanical Stability of Single/Double Screw-Cancellous Bone Fixations of Regan-Morry Type III Ulnar Coronoid Fractures in Adults: CT Measurement and Finite Element Analysis. Orthopaedic surgery, 15(4), 1072-1084. |
MLA | Ye, Hao,et al."Anatomical and Biomechanical Stability of Single/Double Screw-Cancellous Bone Fixations of Regan-Morry Type III Ulnar Coronoid Fractures in Adults: CT Measurement and Finite Element Analysis".Orthopaedic surgery 15.4(2023):1072-1084. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论