题名 | A comparative study on the validity and reliability of anterior, medial, and posterior approaches for internal fixation in the repair of fractures of the coronoid process of the ulna |
作者 | |
发表日期 | 2018-09-11 |
发表期刊 | EUROPEAN JOURNAL OF MEDICAL RESEARCH 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Article |
关键词 | Internal fixation Coronoid process Fracture Posterior approach Anterior approach Medial approach |
其他关键词 | RADIAL HEAD ; ELBOW ; DISLOCATIONS |
摘要 | Background: The coracoid process plays an important role in maintaining the stability of the elbow joint. A fracture of the coronoid process is often treated via surgical approaches, including open reduction and internal fixation, which aim to regain a stable, flexible, and loadable joint. In this study, we compared the anterior, medial, and posterior approaches of internal fixation in the repair of fractures of the coronoid process of the ulna. Methods: In this retrospective study, 147 patients with fractures in the coronoid process of the ulna were recruited and classified into the anterior group (n = 73), the medial group (n = 32), and the posterior group (n = 42) according to the surgical approach used for internal fixation. These patients were assessed with respect to incision, operative time, estimated blood loss, fracture healing, and postoperative complications. The Mayo Elbow Performance Score was used to evaluate any form of disability associated with elbow injuries. Multivariate logistic regression analysis was performed to investigate the factors influencing the efficacy of fractures of the coronoid process of the ulna. Results: In the medial approach group, the operative time was longer, and perioperative blood loss and postoperative drainage volume were obviously increased compared with the anterior and posterior groups. The anterior group exhibited a better postoperative recovery compared with the medial, and posterior groups. Compared with the anterior group, fracture-healing time in the posterior group was further reduced, whereas elbow joint flexion extension and forearm rotation degree improved. Complications were significantly reduced in the posterior approach group compared with the anterior and medial groups. The factors influencing the efficacy of fractures of the coronoid process of the ulna included the Regan-Morrey classification, perioperative blood loss, and the internal fixation approach. Conclusion: In summary, the approach used influences fracture healing or the outcome after osteosynthesis. The posterior internal fixation method produced satisfactory functional outcomes in patients with fractures of the coronoid process of the ulna. |
资助项目 | Science Technology Department of Zhejiang Province [2013C33216]; Health Bureau of Zhejiang Province [2014KYB296]; Yiwu Science and Technology Project [2013-G3-02]; Yiwu High-Level Talents Research Project [201603] |
出版者 | BMC |
出版地 | LONDON |
ISSN | 0949-2321 |
EISSN | 2047-783X |
卷号 | 23期号:1页码:40 |
DOI | 10.1186/s40001-018-0336-7 |
页数 | 8 |
WOS类目 | Medicine, Research & Experimental |
WOS研究方向 | Research & Experimental Medicine |
WOS记录号 | WOS:000444529000001 |
收录类别 | SCIE ; PUBMED ; SCOPUS |
URL | 查看原文 |
PubMed ID | 30205841 |
PMC记录号 | PMC6131958 |
SCOPUSEID | 2-s2.0-85053279728 |
通讯作者地址 | [Chen, Hong-Wei]Department of Orthopedic Surgery,Yiwu Central Hospital,Affiliated Hospital,Wenzhou Medical University,No. 699, Jiangdong Road,Yiwu, Zhejiang,322000,China |
Scopus学科分类 | Medicine (all) |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/16300 |
专题 | 第一临床医学院(信息与工程学院)、附属第一医院_外科学_整形外科 |
通讯作者 | Chen, Hong-Wei |
作者单位 | 1.Department of Orthopedic Surgery,Yiwu Central Hospital,Affiliated Hospital,Wenzhou Medical University,No. 699, Jiangdong Road,Yiwu, Zhejiang,322000,China; 2.Department of Orthopedics,Ningbo NO.6 Hospital,Ningbo,315040,China |
第一作者单位 | 第一临床医学院(信息与工程学院)、附属第一医院_外科学_整形外科 |
通讯作者单位 | 第一临床医学院(信息与工程学院)、附属第一医院_外科学_整形外科 |
第一作者的第一单位 | 第一临床医学院(信息与工程学院)、附属第一医院_外科学_整形外科 |
推荐引用方式 GB/T 7714 | Chen, Hong-Wei,Teng, Xiao-Feng. A comparative study on the validity and reliability of anterior, medial, and posterior approaches for internal fixation in the repair of fractures of the coronoid process of the ulna[J]. EUROPEAN JOURNAL OF MEDICAL RESEARCH,2018,23(1):40. |
APA | Chen, Hong-Wei, & Teng, Xiao-Feng. (2018). A comparative study on the validity and reliability of anterior, medial, and posterior approaches for internal fixation in the repair of fractures of the coronoid process of the ulna. EUROPEAN JOURNAL OF MEDICAL RESEARCH, 23(1), 40. |
MLA | Chen, Hong-Wei,et al."A comparative study on the validity and reliability of anterior, medial, and posterior approaches for internal fixation in the repair of fractures of the coronoid process of the ulna".EUROPEAN JOURNAL OF MEDICAL RESEARCH 23.1(2018):40. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
查看访问统计 |
谷歌学术 |
谷歌学术中相似的文章 |
[Chen, Hong-Wei]的文章 |
[Teng, Xiao-Feng]的文章 |
百度学术 |
百度学术中相似的文章 |
[Chen, Hong-Wei]的文章 |
[Teng, Xiao-Feng]的文章 |
必应学术 |
必应学术中相似的文章 |
[Chen, Hong-Wei]的文章 |
[Teng, Xiao-Feng]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论