摘要 | Objective: Many studies have focused on the accuracy rate of intraarticular injection. However, sometimes, even when the needle enters the joint cavity accurately, it can be difficult to obtain a sufficient amount of joint fluid. This problem may be attributable to the position of the knee during arthrocentesis. The purpose of this prospective study was to determine which position, supine or sitting, would yield more joint fluid during knee arthrocentesis. Design: In this study, 40 knees belonging to 30 patients with osteoarthritis were examined. The patients were randomized between the supine position group (20 knees) and the sitting position group (20 knees). A blind aspiration was performed on each group. The volume of aspirated joint fluid (in milliliters) (V-1) was recorded for each knee. Each knee was then checked by ultrasound immediately after aspiration. If there was more than a depth of 2 mm of knee effusion, then a second knee arthrocentesis was performed using ultrasound guidance. The aspirated joint fluid volume (in milliliters) (V-2) was recorded for each knee. The value V-1/V-1 + V-2 was calculated for each knee. The data were analyzed using the SPSS 16.0 statistical package program. Results: In the supine position group, the dry tap rate was 10% in the first arthrocentesis, and 30% of the knees needed a second arthrocentesis. In the sitting position group, the dry tap rate was 25% in the first arthrocentesis, and 75% of the knees needed a second arthrocentesis. There was a significant difference in the V-1/V-1 + V-2 values between the two groups (P = 0.02). Conclusions: In our study, more joint fluid was aspirated from patients in the supine position than from patients in the sitting position. |
出版者 | LIPPINCOTT WILLIAMS & WILKINS |
出版地 | PHILADELPHIA |
ISSN | 0894-9115 |
EISSN | 1537-7385 |
卷号 | 91期号:7页码:611-615 |
DOI | 10.1097/PHM.0b013e31825a13f0 |
页数 | 5 |
WOS类目 | Rehabilitation ; Sport Sciences |
WOS研究方向 | Rehabilitation ; Sport Sciences |
WOS记录号 | WOS:000305624100008 |
收录类别 | SCIE ; SCOPUS |
URL | 查看原文 |
PubMed ID | 22710881 |
SCOPUSEID | 2-s2.0-84862853804 |
通讯作者地址 | [Zhang, Qiankun]Lishui Ctr Hosp, Dept Rheumatol, Lishui 323000, Zhejiang, Peoples R China. |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/15235 |
专题 | 附属第一医院_风湿免疫科 第一临床医学院(信息与工程学院)、附属第一医院_科研中心 |
通讯作者 | Zhang, Qiankun |
作者单位 | 1.Lishui Ctr Hosp, Dept Rheumatol, Lishui 323000, Zhejiang, Peoples R China; 2.Lishui Ctr Hosp, Dept Ultrason, Lishui 323000, Zhejiang, Peoples R China; 3.Lishui Ctr Hosp, Dept Orthopaed Surg, Lishui 323000, Zhejiang, Peoples R China; 4.Wenzhou Med Coll, Affiliated Hosp 1, Dept Rheumatol, Wenzhou, Zhejiang, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Qiankun,Zhang, Ting,Lv, Honghua,et al. Comparison of Two Positions of Knee Arthrocentesis How to Obtain Complete Drainage[J]. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION,2012,91(7):611-615. |
APA | Zhang, Qiankun., Zhang, Ting., Lv, Honghua., Xie, Lidan., Wu, Weidong., ... & Wu, Xuelian. (2012). Comparison of Two Positions of Knee Arthrocentesis How to Obtain Complete Drainage. AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 91(7), 611-615. |
MLA | Zhang, Qiankun,et al."Comparison of Two Positions of Knee Arthrocentesis How to Obtain Complete Drainage".AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION 91.7(2012):611-615. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论