题名 | Efficacy and outcome of open reduction and internal fixation with mini-plate in ulnar coronoid process fractures |
作者 | |
发表日期 | 2016-12-31 |
发表期刊 | INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Article |
关键词 | Unlar coronoid process fracture fracture fixation mini-plate |
其他关键词 | RADIAL HEAD ; ELBOW ; STABILITY ; REPAIR ; DISLOCATIONS ; KINEMATICS |
摘要 | Aim: This study aimed to investigate clinical efficacy of open reduction and mini-plate fixation for the ulnar coronoid process fractures. Methods: 21 cases of ulnar coronoid process fractures treated with open reduction and mini-plate fixation were enrolled. Causes of injury included traffic injuries in 4 cases and fall on the ground in 17 cases. There were 10 cases of type I, 9 cases of type II and 2 cases of type III. Time from injury to operation ranged from 2 hours to 10 days ( mean, 3.7 days). Fractures were fixed with mini-plate. Results: All cases were followed-up for 12-25 months ( average 15.1 months). The bony union time was 8 similar to 14 weeks with an average of 10.6 weeks. No 1 oosening or breakage of the internal fixation was found. Mean flexion at the last follow-up was 124 degrees ( range, 90 degrees-140 degrees), mean extension loss was 18 degrees ( range, 0 degrees-50 degrees), mean pronation was 65 degrees ( range, 40 degrees-85 degrees) while mean supination was 63 degrees ( range, 35 degrees-85 degrees), showing significant difference when compared with that before operation ( P < 0.05). According to MEPS elbow performance score, the results were excellent in 14 cases, good in 5 cases, fair in 1 case and poor in 1 case. According to Broberg and Morrey elbow performance score, the results were excellent in 11 cases, good in 7 cases, fair in 2 case and poor in 1 case. Conclusion: Open reduction and mini-plate fixation, provides sufficient stability for early functional exercise, is a effective treatment of ulnar coronoid process fractures. |
出版者 | E-CENTURY PUBLISHING CORP |
出版地 | MADISON |
ISSN | 1940-5901 |
卷号 | 9期号:5页码:8858-8864 |
页数 | 7 |
WOS类目 | Medicine, Research & Experimental |
WOS研究方向 | Research & Experimental Medicine |
WOS记录号 | WOS:000379956500158 |
收录类别 | SCIE ; SCOPUS |
URL | 查看原文 |
SCOPUSEID | 2-s2.0-84971441851 |
通讯作者地址 | [Pan, Jun]Department of Orthopedics,Yiwu Central Hospital,Affiliated Hospital of Wenzhou Medical University,Yiwu,322000,China |
Scopus学科分类 | Biochemistry, Genetics and Molecular Biology (all) |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/14383 |
专题 | 温州医科大学 |
通讯作者 | Pan, Jun |
作者单位 | Department of Orthopedics,Yiwu Central Hospital,Affiliated Hospital of Wenzhou Medical University,Yiwu,322000,China |
第一作者单位 | 温州医科大学 |
通讯作者单位 | 温州医科大学 |
第一作者的第一单位 | 温州医科大学 |
推荐引用方式 GB/T 7714 | Chen, Hongwei,Pan, Jun. Efficacy and outcome of open reduction and internal fixation with mini-plate in ulnar coronoid process fractures[J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE,2016,9(5):8858-8864. |
APA | Chen, Hongwei, & Pan, Jun. (2016). Efficacy and outcome of open reduction and internal fixation with mini-plate in ulnar coronoid process fractures. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 9(5), 8858-8864. |
MLA | Chen, Hongwei,et al."Efficacy and outcome of open reduction and internal fixation with mini-plate in ulnar coronoid process fractures".INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE 9.5(2016):8858-8864. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
查看访问统计 |
谷歌学术 |
谷歌学术中相似的文章 |
[Chen, Hongwei]的文章 |
[Pan, Jun]的文章 |
百度学术 |
百度学术中相似的文章 |
[Chen, Hongwei]的文章 |
[Pan, Jun]的文章 |
必应学术 |
必应学术中相似的文章 |
[Chen, Hongwei]的文章 |
[Pan, Jun]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论