科研成果详情

题名A novel ophthalmic viscosurgical device-free phakic intraocular lens implantation makes myopic surgery safer
作者
发表日期2020-04-07
发表期刊EYE AND VISION   影响因子和分区
语种英语
原始文献类型Article
关键词Phakic intraocular lens implantation Ophthalmic viscosurgical device-free Intraocular pressure Complications
其他关键词CENTRAL HOLE ; FOLLOW-UP ; CLINICAL-OUTCOMES ; MODERATE ; PRESSURE ; HYDROIMPLANTATION ; PREVALENCE
摘要Purpose To assess the efficacy and safety of a novel ophthalmic viscosurgical device-free (OVD-free) method for posterior chamber phakic intraocular lens (PIOL) implantation in myopic eyes. Methods In this retrospective cohort study, the medical records of myopic eyes that underwent PIOL (Implantable Collamer Lens, ICL) implantation for myopia correction at the Eye Hospital of Wenzhou Medical University between May 2015 and March 2017 were reviewed. A total of 49 eyes with complete data that met follow up requirements (2 h, 1 day, 1 week, 3 months postoperatively) were recruited. Based on the surgical techniques used, the eyes were divided into the OVD-free method group and the standard method group. The clinical data, including intraocular pressure (IOP), corrected distance visual acuity (CDVA) and spherical equivalent (SE), at each follow-up were collected for comparison. Endothelial cell loss and complications were also investigated. Results Twenty-one eyes received the standard method, and 28 eyes received the OVD-free method. A rise in IOP > 22 mmHg at 2 h was noted in 14 eyes (66.7%) in the standard group and none (0%) in the OVD-free group (p < 0.001). The rise in IOP from baseline was significantly higher at 2 h in the standard group (10.5 +/- 5.2 mmHg vs. 2.2 +/- 3.3 mmHg, difference: 8.3, 95% CI 5.8 to 10.8; p < 0.001). There was a significant difference in the time course of LogMAR CDVA changes between the two groups (p = 0.047). The LogMAR CDVA was significantly better in the OVD-free method group compared to the standard group at 1 day (- 0.076, 95% CI - 0.134 to - 0.018; p = 0.012), 1 week (- 0.071, 95% CI - 0.135 to - 0.007; p = 0.03), but not at 3 months (- 0.046, 95% CI - 0.107 to 0.015; p = 0.134). There was no significant difference in the time course of SE changes between the two groups (p = 0.471; p = 0.705). In the OVD-free group, mean endothelial cell loss was 4.6% at 3 months (2522 +/- 281 vs. 2407 +/- 226 cells/mm(2), difference: -115, 95% CI - 295 to 65; p = 0.187). No complications were reported in both groups except for the early IOP elevation in the standard group during the observation period. Conclusions The OVD-free method is safe and efficient for ICL implantation. It can be a safer method of ICL implantation compared to the standard method in that it completely eliminates ophthalmic viscoelastic devices-related complications without causing additional complications.
资助项目National Natural Science Foundation of ChinaNational Natural Science Foundation of China (NSFC) [81570869]; Zhejiang Provincial Natural Science Foundation of ChinaNatural Science Foundation of Zhejiang Province [Y2110784]; Zhejiang Provincial Foundation of China for Distinguished Young Talents in Medicine and Health [2010QNA018]; Wenzhou Key Team of Scientific and Technological Innovation [C20170002]; Foundation of Wenzhou City Science & Technology Bureau [Y20140705]; Engineering Development Project of Ophthalmology and Optometry [GCKF201601]
出版者BMC
出版地LONDON
ISSN2326-0254
卷号7期号:1页码:18
DOI10.1186/s40662-020-00185-4
页数9
WOS类目Ophthalmology
WOS研究方向Ophthalmology
WOS记录号WOS:000525257200001
收录类别SCIE ; PUBMED ; CSCD ; SCOPUS
学科领域医药、卫生
URL查看原文
CSCD记录号CSCD:6927074
PubMed ID32280722
PMC记录号PMC7137322
SCOPUSEID2-s2.0-85100460676
通讯作者地址[Yu, A-Yong]The Eye Hospital of Wenzhou Medical University,270 Xueyuan West Road, Zhejiang,Wenzhou,325000,China
Scopus学科分类Health Professions (miscellaneous);Ophthalmology
引用统计
被引频次:6[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符https://kms.wmu.edu.cn/handle/3ETUA0LF/1382
专题眼视光学院(生物医学工程学院)、附属眼视光医院
眼视光学院(生物医学工程学院)、附属眼视光医院_白内障中心
通讯作者Yu, A-Yong
作者单位
The Eye Hospital of Wenzhou Medical University,270 Xueyuan West Road, Zhejiang,Wenzhou,325000,China
第一作者单位眼视光学院(生物医学工程学院)、附属眼视光医院
通讯作者单位眼视光学院(生物医学工程学院)、附属眼视光医院
第一作者的第一单位眼视光学院(生物医学工程学院)、附属眼视光医院
推荐引用方式
GB/T 7714
Pan, An-Peng,Wen, Li-Jin,Shao, Xu,et al. A novel ophthalmic viscosurgical device-free phakic intraocular lens implantation makes myopic surgery safer[J]. EYE AND VISION,2020,7(1):18.
APA Pan, An-Peng., Wen, Li-Jin., Shao, Xu., Zhou, Kai-Jing., Wang, Qin-Mei., ... & Yu, A-Yong. (2020). A novel ophthalmic viscosurgical device-free phakic intraocular lens implantation makes myopic surgery safer. EYE AND VISION, 7(1), 18.
MLA Pan, An-Peng,et al."A novel ophthalmic viscosurgical device-free phakic intraocular lens implantation makes myopic surgery safer".EYE AND VISION 7.1(2020):18.

条目包含的文件

条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Pan, An-Peng]的文章
[Wen, Li-Jin]的文章
[Shao, Xu]的文章
百度学术
百度学术中相似的文章
[Pan, An-Peng]的文章
[Wen, Li-Jin]的文章
[Shao, Xu]的文章
必应学术
必应学术中相似的文章
[Pan, An-Peng]的文章
[Wen, Li-Jin]的文章
[Shao, Xu]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。