题名 | Determination of azasetron hydrochloride in rabbit plasma by liquid chromatography tandem mass spectrometry and its application |
作者 | |
发表日期 | 2011-10 |
发表期刊 | BIOMEDICAL CHROMATOGRAPHY 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Article |
关键词 | LC-MS/MS azasetron hydrochloride pharmacokinetics plasma |
其他关键词 | Y-25130 |
摘要 | A sensitive and selective liquid chromatography tandem mass spectrometry method for determination of azasetron hydrochloride in rabbit plasma was developed. After addition of doxapram hydrochloride as internal standard (IS), protein precipitation by 10% trichloroacetic acid was used as sample preparation. Chromatographic separation was achieved on a Zorbax SB-C(18) (2.1 50 mm, 3.5 mm) column with acetonitrile-water as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used to quantification using target fragment ions m/z 349.9 -> 223.5 for azasetron hydrochloride and m/z 378.9 -> 291.8 for the IS. Calibration plots were linear over the range of 6-1000 ng/mL for azasetron hydrochloride in plasma. The lower limit of quantitation for azasetron hydrochloride was 6 ng/mL. The mean recovery of azasetron hydrochloride from plasma was in the range 85.6-92.7%. The RSDs of intra-day and inter-day precision were both less than 12%. This method is simple and sensitive enough to be used in pharmacokinetic research for determination of azasetron hydrochloride in rabbit plasma. Copyright (C) 2010 John Wiley & Sons, Ltd. |
资助项目 | Analyzing and Testing Foundation of Zhejiang Province [2007F80010] |
出版者 | WILEY-BLACKWELL |
出版地 | MALDEN |
ISSN | 0269-3879 |
EISSN | 1099-0801 |
卷号 | 25期号:10页码:1107-1111 |
DOI | 10.1002/bmc.1578 |
页数 | 5 |
WOS类目 | Biochemical Research Methods ; Biochemistry & Molecular Biology ; Chemistry, Analytical ; Pharmacology & Pharmacy |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry ; Pharmacology & Pharmacy |
WOS记录号 | WOS:000295143500006 |
收录类别 | SCIE ; PUBMED ; SCOPUS |
URL | 查看原文 |
PubMed ID | 21204117 |
SCOPUSEID | 2-s2.0-80052522677 |
通讯作者地址 | [Wang, Xianqin]Wenzhou Med Coll, Analyt & Testing Ctr, University Town 325035, Wenzhou, Peoples R China. |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/13569 |
专题 | 附属第一医院 实验动物中心 基础医学院(机能实验教学中心)_基础医学实验教学中心_机能实验教学中心(挂靠、校级) |
通讯作者 | Wang, Xianqin |
作者单位 | 1.Wenzhou Med Coll, Analyt & Testing Ctr, University Town 325035, Wenzhou, Peoples R China; 2.Wenzhou Med Coll, Affiliated Hosp 1, Wenzhou 325000, Peoples R China; 3.Wenzhou Med Coll, Funct Expt Teaching Ctr, Wenzhou 325035, Peoples R China; 4.Wenzhou Med Coll, Lab Anim Ctr, Wenzhou 325035, Peoples R China |
第一作者单位 | 附属第一医院 |
通讯作者单位 | 温州医科大学 |
第一作者的第一单位 | 附属第一医院 |
推荐引用方式 GB/T 7714 | Lin, Guanyang,Ma, Jianshe,Zhu, Jiayin,et al. Determination of azasetron hydrochloride in rabbit plasma by liquid chromatography tandem mass spectrometry and its application[J]. BIOMEDICAL CHROMATOGRAPHY,2011,25(10):1107-1111. |
APA | Lin, Guanyang, Ma, Jianshe, Zhu, Jiayin, Yang, Xuezhi, Hu, Lufeng, & Wang, Xianqin. (2011). Determination of azasetron hydrochloride in rabbit plasma by liquid chromatography tandem mass spectrometry and its application. BIOMEDICAL CHROMATOGRAPHY, 25(10), 1107-1111. |
MLA | Lin, Guanyang,et al."Determination of azasetron hydrochloride in rabbit plasma by liquid chromatography tandem mass spectrometry and its application".BIOMEDICAL CHROMATOGRAPHY 25.10(2011):1107-1111. |