科研成果详情

题名Objective and subjective visual quality after implantation of all optic zone diffractive multifocal intraocular lenses: a prospective, case-control observational study
作者
发表日期2016-11
发表期刊BRITISH JOURNAL OF OPHTHALMOLOGY   影响因子和分区
语种英语
原始文献类型Article
关键词Clinical Trial Optics and Refraction Lens and zonules
其他关键词DOUBLE-PASS SYSTEM ; LASER VISION CORRECTION ; PSEUDOPHAKIC EYES ; IMAGE QUALITY ; CHROMATIC ABERRATIONS ; CLINICAL-EVALUATION ; CATARACT-SURGERY ; LIGHT SCATTER ; PERFORMANCE ; INSTRUMENT
摘要Background and aims To evaluate the objective and subjective optical quality of all optic zone diffractive multifocal intraocular lens (IOL). Methods Fifty patients (50 eyes) having phacoemulsification and IOL implantation surgery were enrolled. 25 patients were implanted with all optic zone diffractive multifocal IOL and 25 patients with monofocal IOL. Objective optical quality parameters under 4mm pupil using Optical Quality Analysis System (OQAS), subjective visual acuity (VA) at 85cd/m(2) luminance and questionnaire concerning halo and visual function were assessed. Results The multifocal group gained similar objective optical outcomes, such as OQAS values at contrast 100%, 20%, 9%, modulation transfer function cut-off and Strehl ratio, as the monofocal group. Objective scatter index (OSI) was significantly better in the monofocal group. Distance corrected near VA, uncorrected near VA, distance corrected intermediate VA and uncorrected intermediate VA were significantly better in the multifocal group. The difference in uncorrected distance VA and best corrected distance VA between the monofocal and multifocal groups was not significant. Mild halos and glare were reported in both groups and a significant difference between the two groups was not observed; however, moderate glare and halos were reported only in the multifocal group (2/25). There was no significant difference between the two groups when visual function was compared. Conclusions All optic zone diffractive multifocal IOLs provided almost the same objective optical quality as monofocal IOLs did under 4mm pupil besides good all distance visual performance, but with greater OSI, indicating that implantation provides good optical quality in daytime but with more intraocular scatter light. Trial registration number NCT02234635, post-results.
资助项目Natural Science Foundation of Zhejiang Province, ChinaNatural Science Foundation of Zhejiang Province [LY13H120005]; National Natural Science Foundation of ChinaNational Natural Science Foundation of China (NSFC) [81200672]
出版者BMJ PUBLISHING GROUP
出版地LONDON
ISSN0007-1161
EISSN1468-2079
卷号100期号:11页码:1530-1535
DOI10.1136/bjophthalmol-2015-307135
页数6
WOS类目Ophthalmology
WOS研究方向Ophthalmology
WOS记录号WOS:000388004900016
收录类别SCIE ; PUBMED ; SCOPUS
URL查看原文
PubMed ID26903522
SCOPUSEID2-s2.0-84960172510
通讯作者地址[Li, Jin]Department of Cataract,Eye Hospital of Wenzhou Medical University,Wenzhou, Zhejiang,325000,China
Scopus学科分类Ophthalmology;Sensory Systems;Cellular and Molecular Neuroscience
TOP期刊TOP期刊
引用统计
被引频次:24[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符https://kms.wmu.edu.cn/handle/3ETUA0LF/13527
专题眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_白内障专科
通讯作者Li, Jin
作者单位
Department of Cataract,Eye Hospital of Wenzhou Medical University,Wenzhou, Zhejiang,325000,China
第一作者单位眼视光学院(生物医学工程学院)、附属眼视光医院
通讯作者单位眼视光学院(生物医学工程学院)、附属眼视光医院
第一作者的第一单位眼视光学院(生物医学工程学院)、附属眼视光医院
推荐引用方式
GB/T 7714
Chen, Tianyu,Yu, Fang,Lin, Huayou,et al. Objective and subjective visual quality after implantation of all optic zone diffractive multifocal intraocular lenses: a prospective, case-control observational study[J]. BRITISH JOURNAL OF OPHTHALMOLOGY,2016,100(11):1530-1535.
APA Chen, Tianyu., Yu, Fang., Lin, Huayou., Zhao, Yinying., Chang, Pingjun., ... & Li, Jin. (2016). Objective and subjective visual quality after implantation of all optic zone diffractive multifocal intraocular lenses: a prospective, case-control observational study. BRITISH JOURNAL OF OPHTHALMOLOGY, 100(11), 1530-1535.
MLA Chen, Tianyu,et al."Objective and subjective visual quality after implantation of all optic zone diffractive multifocal intraocular lenses: a prospective, case-control observational study".BRITISH JOURNAL OF OPHTHALMOLOGY 100.11(2016):1530-1535.

条目包含的文件

条目无相关文件。
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[Chen, Tianyu]的文章
[Yu, Fang]的文章
[Lin, Huayou]的文章
百度学术
百度学术中相似的文章
[Chen, Tianyu]的文章
[Yu, Fang]的文章
[Lin, Huayou]的文章
必应学术
必应学术中相似的文章
[Chen, Tianyu]的文章
[Yu, Fang]的文章
[Lin, Huayou]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。