题名 | Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses |
作者 | |
发表日期 | 2021-01 |
发表期刊 | ANNALS OF TRANSLATIONAL MEDICINE 影响因子和分区 |
语种 | 英语 |
原始文献类型 | Article |
关键词 | Asymmetric refractive diffractive multifocal intraocular lens visual quality |
摘要 | Background: To compare the visual performance of MF30 asymmetric refractive multifocal intraocular lenses (MIOLs) with ZMB00 all optic zone diffractive MIOLs. Methods: This is a prospective study. Patients that underwent phacoemulsification were divided into two groups according to the type of MIOLs used: 35 patients were implanted with asymmetric refractive MIOLs and 35 patients with all optic zone diffractive MIOLs. Visual acuity (VA), refraction, defocus curves, objective optical quality, and a questionnaire evaluating quality of life were measured at 3 months postoperatively. Results: There were no significant differences between the two groups in uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), best-corrected distance visual acuity (BCDVA), or distance-corrected near visual acuity (DCNVA). However, the uncorrected intermediate VA was 0.24 +/- 0.10 in the refractive group and 0.31 +/- 0.13 in the diffractive group (P<0.05), and the distance-corrected intermediate VA was 0.22 +/- 0.09 in the refractive group and 0.31 +/- 0.14 in the diffractive group (P<0.05). Defocus curves showed two peaks of maximum vision in both groups. However, the curve between the two peaks in the refractive group was smoother than that of the diffractive group. The modulated transfer function cut-off frequency was 22.74 +/- 12.29 c/d in the refractive group and 30.50 +/- 10.04 c/d in the diffractive group (P<0.05). The Optical Quality Analysis System (OQAS) values 100% (OV100%) was 0.75 +/- 0.41 in the refractive group and 1.02 +/- 0.34 in the diffractive group (P<0.05), while the OV20% was 0.52 +/- 0.34 in the refractive group and 0.71 +/- 0.25 in the diffractive group (P<0.05). There was no significant difference between the two groups in overall satisfaction, spectacle independence ratio, or visual interference phenomenon. Conclusions: Both MIOLs achieve good VA at distance and near vision. Oculentis MF30 showed better intermediate VA, and Tecnis ZMB00 appears to have better objective visual quality. |
出版者 | AME PUBL CO |
出版地 | SHATIN |
ISSN | 2305-5839 |
EISSN | 2305-5847 |
卷号 | 9期号:2页码:144 |
DOI | 10.21037/atm-20-7777 |
页数 | 9 |
WOS类目 | Oncology ; Medicine, Research & Experimental |
WOS研究方向 | Oncology ; Research & Experimental Medicine |
WOS记录号 | WOS:000636046800022 |
收录类别 | SCIE ; PUBMED |
URL | 查看原文 |
PubMed ID | 33569446 |
PMC记录号 | PMC7867926 |
通讯作者地址 | [Li, Jin]Wenzhou Med Univ, Eye Hosp, Cataract Dept, 270 West Xueyuan Rd, Wenzhou 325000, Peoples R China. |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | https://kms.wmu.edu.cn/handle/3ETUA0LF/1194 |
专题 | 眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_白内障专科 眼视光学院(生物医学工程学院)、附属眼视光医院_玻璃体视网膜组 |
通讯作者 | Li, Jin |
作者单位 | 1.Wenzhou Med Univ, Eye Hosp, Cataract Dept, 270 West Xueyuan Rd, Wenzhou 325000, Peoples R China; 2.Wenzhou Med Univ, Eye Hosp, Retina Dept, Wenzhou, Peoples R China |
第一作者单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_白内障专科 |
通讯作者单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_白内障专科 |
第一作者的第一单位 | 眼视光学院(生物医学工程学院)、附属眼视光医院_杭州院区_白内障专科 |
推荐引用方式 GB/T 7714 | Ye, Lingying,Chen, Tianyu,Hu, Zhixiang,et al. Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses[J]. ANNALS OF TRANSLATIONAL MEDICINE,2021,9(2):144. |
APA | Ye, Lingying, Chen, Tianyu, Hu, Zhixiang, Yang, Qingwen, Su, Qiudong, & Li, Jin. (2021). Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses. ANNALS OF TRANSLATIONAL MEDICINE, 9(2), 144. |
MLA | Ye, Lingying,et al."Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses".ANNALS OF TRANSLATIONAL MEDICINE 9.2(2021):144. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论