科研成果详情

题名小儿异丙酚靶控输注系统准确性的评价
其他题名Evaluation of the accuracy of administration of propofol by a TCI system in children
作者
发表日期2006
发表期刊中华麻醉学杂志   影响因子和分区
语种中文
原始文献类型期刊论文
关键词儿童 二异丙酚 药物释放系统 药代动力学
摘要目的 建立小儿异丙酚药代学参数的靶控输注(TCI)系统,评价系统的准确性。方法 24例ASAⅠ级择期手术小儿,分为2组(n=12),A组:≥3岁且〈5岁;B组:≥5岁且〈10岁,应用连庆泉等报道的小儿异丙酚药代动力学参数以及Stanpump软件,微机连接Graseby 3500输液泵。恒定血浆靶浓度3μg·ml^-1变速输注持续1h,间断采集动脉血持续1.5h。用高效液相法测定异丙酚血浆药物浓度,并计算系统的执行误差中位数(MDPE)、不含TCI开始5min的执行误差中位数(MDPEl)、执行误差绝对值的中位数(MDAPE)、分散度和摆动度。结果两组异丙酚的实测浓度在TCI开始40min内均高于靶浓度(P〈0.05),后渐接近靶浓度,至TCI50min时与靶浓度差异无统计学意义。停止TCI后实测浓度比预测浓度低(P〈0.01)。A、B组TCI期间系统的MDPE分别为27%和26%、MDPEl分别为7%和12%、MDAPE分别为27%和26%、分散度分别为-0.75%·h^-1和-0.80%·h^-1、摆动度分别为23%和24%,停止TCI后系统的MDPE分别为-30%和-25%,MDAPE分别为30%和25%,摆动度分别为9%和9%,分散度分别为0.31%·h^-1和0.38%·h^-1。结论 本研究中小儿TCI输注系统的偏离性较小,精确度较高且分散度小,能维持稳定的血药浓度,符合临床要求。
其他摘要Objective To develop a target-controlled infusion (TCI) system incorporating population pharmacokinetics of propofol for children and evaluate its accuracy. Methods The TCI system was composed of a Samsung Q20 laptop computer, Graseby 3500 infusion pump, Stanpump software (Version 1.0 designed by Shafer et al. Stanford) and pharmacokinetic parameter set for propofol in children reported by Lian et al. Twenty-four ASA Ⅰ children undergoing elective orthopedic or urological surgery under general anesthesia were divided into 2 age groups- group A 3-5 yrs ( n = 12) and group B 5-10 yrs ( n = 12). Radial artery and internal jugular vein were cannulated. The pediatric patients were sedated with ketamine 4mg·kg^-1 IM (uncooperative patients) or 2 mg·kg^-1 Ⅳ (cooperative patients). Anesthesia was induced with fentanyl 3 μg·kg^-1, propofol by TCI and vecuronium 0.1mg·kg^-1. Target plasma concentration of propofol was set at 3 μg·ml^-1. TCI of propofol was maintained for 60 min. Arterial blood samples were taken at 1, 3, 5, 10, 20, 30, 40, 50 and 60min after TCI was started and at 2.5, 5, 10, 20 and 30 min after termination of TCI for determination of blood propofol concentration by HPLC. The median performance error (MDPE), MDPE without first five minutes (MDPE1), median absolute performance error (MDAPE), wobble and divergence were calculated. Results During the first 40 minutes of TCI there was a remarkable difference between the measured plasma propofol concentration (Cm) and the target plasma concentration (Cp). The difference was narrowing gradually until the 50 min of TCI. After the termination of TCI the Cm was significantly lower than Cp. The MDPE was 27% in group A and 26% in group B; MDPE1 was 7% (A) and 12% (B) and MDAPE 27% (A) and 26% (B) during TCI. The wobble was 23% (A) and 24% (B) and the divergence -0.75%·h^-1(A) and -0.80%·h^-1 respectively. Conclusion The bias and divergence of our TCI system for propofol are small and the accuracy is high and a stable plasma concentration of propofol can be maintained in children.
资助项目浙江省医药卫生优秀青年科技人才专项科研基金
ISSN0254-1416
卷号26期号:2页码:118-121
DOI10.3760/j.issn:0254-1416.2006.02.008
页数4
收录类别CSCD ; 万方 ; PKU ; 北大核心 ; ISTIC
学科领域医药、卫生 ; 预防医学、卫生学 ; 外科学
URL查看原文
CSCD记录号CSCD:2334004
引用统计
文献类型期刊论文
条目标识符https://kms.wmu.edu.cn/handle/3ETUA0LF/100180
专题第二临床医学院、附属第二医院、育英儿童医院
眼视光学院(生物医学工程学院)、附属眼视光医院_药剂科
作者单位
1.温州医学院附属第二医院麻醉科 ;
2.温州医学院药剂科 ;
3.黑龙江华翔科技开发有限公司 ;
4.华中科技大学同济医学院附属协和医院麻醉科, 武汉, 430022
第一作者单位第二临床医学院,附属第二医院、育英儿童医院;  附属第二医院;  麻醉科
第一作者的第一单位第二临床医学院,附属第二医院、育英儿童医院
推荐引用方式
GB/T 7714
连庆泉,刘华程,上官王宁,等. 小儿异丙酚靶控输注系统准确性的评价[J]. 中华麻醉学杂志,2006,26(2):118-121.
APA 连庆泉., 刘华程., 上官王宁., 徐旭仲., 王增寿., ... & 姚尚龙. (2006). 小儿异丙酚靶控输注系统准确性的评价. 中华麻醉学杂志, 26(2), 118-121.
MLA 连庆泉,et al."小儿异丙酚靶控输注系统准确性的评价".中华麻醉学杂志 26.2(2006):118-121.

条目包含的文件

下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
ZHMZ200602008.CAJ(218KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
查看访问统计
谷歌学术
谷歌学术中相似的文章
[连庆泉]的文章
[刘华程]的文章
[上官王宁]的文章
百度学术
百度学术中相似的文章
[连庆泉]的文章
[刘华程]的文章
[上官王宁]的文章
必应学术
必应学术中相似的文章
[连庆泉]的文章
[刘华程]的文章
[上官王宁]的文章
相关权益政策
暂无数据
收藏/分享
文件名: ZHMZ200602008.CAJ
格式: CAJ VIEWER
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。